ADTRAN NetVanta T1/FT1 User Manual

Wan-t1 n, Rj-48c) c

Advertising
background image

NetVanta T1/FT1 Network Interface Module (NIM)

P/N 1202862L1

For more detailed documentation, visit us online at

www.adtran.com

.

Quick Start Guide

®

Quick Start Guide, 61202862L1-13D, November 2006

Copyright © 2006 ADTRAN, All Rights Reserved

S

PECIFICATIONS

Operating Modes Frame Relay, Multilink Frame Relay,

PPP, Multilink PPP, HDLC

T1/FT1 Interface

Supported Standards: AT&T TR 62411,
AT&T TR 54016, Bellcore TR 194, ANSI T1.403
Line Rate: 1.544 Mbps ±75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of
64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long),
0 to 655 ft (short)
DS0 Assignment: Programmable
Connector: RJ-48C

Clock Source

Network, Internal

Diagnostics

Test Pattern Generation and Detection: QRSS, 511,
2

15

- 1, 2

20

- 1, all ones, all zeros

Network loopbacks (local and remote); responds to
both inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data
(15 minutes and 24 hours)

Compliance

FCC Part 15 Class A, EN 55022 Class A
ACTA/FCC Part 68, IC CS-03
UL/CUL 60950

Physical

Dimensions: 2.75-inch W x 4.25-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing

NetVanta modules should be installed only in

NetVanta Series products.

WAN-T1

DBU

I

NSTALLATION

I

NSTRUCTIONS

1.

Remove the power from the unit.

2.

Slide the option module into the option slot until the module is
firmly seated against the chassis.

3.

Secure the pins at both edges of the module.

4.

Connect the cables to the associated device(s).

5.

Complete installation of the base unit.

6.

Restore power to the unit.

For NetVanta modules with outside plant

connections, ensure that all cables are

removed from the module before installing or

removing it from the NetVanta chassis.

WAN-T1 N

ETWORK

(RJ-48C) C

ONNECTION

P

INOUTS

Pin

Name

Description

1

R1

Receive data from the network - Ring 1

2

T1

Receive data from the network - Tip 1

3

Unused

4

R

Transmit data toward the network - Ring

5

T

Transmit data toward the network - Tip

6-8

Unused

An optional Dial Backup Interface Module (DIM) is

required for dial backup applications.
For a description of the DBU pinouts, refer to the

Quick Start Guide included with your DIM

shipment.

Important: For additional details on product

features, specifications, installation, and safety, refer

to the appropriate Hardware Installation Guide on

the ADTRAN OS System Documentation CD

shipped with the base unit and available online at

www.adtran.com.

Advertising