Siemens HB38GB590 User Manual

Page 5

Advertising
background image

Appliance under worktop – Fig. 1
To ventilate the appliance, the intermediate floor must have a

ventilation cut-out.
Secure the worktop to the fitted units.
If the appliance is installed under a hob, the following minimum

dimensions must be adhered to (including substructure, if

applicable):

The minimum worktop thickness a results from the minimum

required dimension b.

Observe the installation instructions for the hob.
Appliance in a tall unit ­ Figs 2+4

The appliance may also be installed in a tall unit.
There must be a gap between the intermediate floors and the

mounting wall of approx. 20 mm in order to provide ventilation

to the oven.
Only fit the appliance at a height where removing baking trays

does not present a problem.
Corner installation ­ Fig. 3

To ensure that the appliance door can be opened in the case of

corner installation, take account of dimension D. Dimension E is

dependent on the thickness of the unit front under the handle.

Connecting the appliance to the power supply

The appliance corresponds to protection class I and may only

be operated with a protective earth connection.
The appliance must be disconnected from the power supply for

all installation work.
The appliance must only be connected with the power cable

provided. Connect the power cable to the back of the appliance

(listen for the click).
A longer power cable can be obtained from the after-sales

service.
The power cable may only be replaced by a cable from the

original manufacturer, obtainable via the after-sales service.
Contact protection must be ensured by the installation.
Power cable with a plug with earthing contact
The appliance must only be connected to a properly installed

protective contact socket.
If the plug is no longer accessible following installation, an all-

pole isolating switch must be present on the installation side

with a contact gap of at least 3 mm.

Power cable without a plug with earthing contact

Only allow a licenced professional to connect the appliance. He

is subject to the regulations of the local electricity provider.
An all-pole isolating switch with at least a 3 mm contact gap

must be fitted in the installation. Identify the phase and neutral

(zero) conductor in the connection socket. Incorrect connection

may cause damage to the appliance.
only connect as per the connection diagram. See the rating

plate for the voltage. Connect the wires of the mains power

cable according to the colour coding: green/yellow = PE

conductor

<

, blue = neutral conductor, brown = phase (external

conductor).
UK and Australia only

Connect using at least a 16 A plug or protect with a 16 A fuse.
Only in Sweden, Finland and Norway

The appliance can also be connected using the plug provided

which has an earthing contact system. This must still be

accessible after installation. If this is not the case, an all-pole

isolating switch must be used on the installation side with a

contact gap of at least 3 mm.

Securing the appliance ­ Fig. 5

If necessary, fit the spacer.

Fully insert the appliance and centre it.

Screw the appliance into place.

The gap between the worktop and the appliance must not be

closed by additional battens.

Removal
Disconnect the appliance from the power supply. Undo the

securing screws. Raise the appliance slightly and pull it out

completely.

fr

Þ

Notice de montage

Préparation du meuble - fig. 1

Uniquement une installation effectuée selon cette notice de

montage garantit une utilisation en toute sécurité. En cas de

dommages résultant d'une installation incorrecte, l'installateur

est responsable.

Les meubles d'encastrement doivent résister à des

températures jusqu'à 90 °C , les façades des meubles

attenants à des températures jusqu'à 70 °C.

Effectuer tous les travaux de découpe sur le meuble et sur le

plan de travail avant d'encastrer les appareils. Enlever les

copeaux, le fonctionnement des composants électriques peut

être compromis.

Attention lors de l'encastrement! Des éléments accessibles

pendant le montage peuvent posséder des arêtes vives.

Porter des gants de protection pour éviter des coupures

La prise de raccordement de l'appareil doit se situer dans la

zone de la surface B ou à l'extérieur de la zone

d'encastrement.

Une fente d'aération de 5mm est nécessaire entre l'appareil et

les façades des meubles attenants.

Les meubles non fixés doivent être vissés au mur avec une

équerre usuelle du commerce C.

L'appareil sous le plan de travail - fig. 1
Pour l'aération de l'appareil, le faux-plancher doit présenter une

découpe de ventilation.
Fixer le plan de travail sur le meuble d'encastrement.
Si l'appareil est encastré sous une table de cuisson, les cotes

minimales suivantes doivent être respectées (le cas échéant,

construction support incluse) :

Hob type

a
Fixed

a
Flush with

surrounding

surfaces

b

Induction hob

37 mm

38 mm

5 mm

Full-surface induction hob

43 mm

48 mm

5 mm

Gas hob

32 mm

42 mm

5 mm

Electric hob

22 mm

24 mm

2 mm