Prior to installation

2. Insert the one-way flap into the bearing

apertures on the air-pipe connector.

If the exhaust air is going to be
discharged into the open,
a telescopic
wall box should be fitted into the outside
wall.

For optimum extractor hood efficiency:
❑ Short, smooth air exhaust pipe.
❑ As few bends in the pipe as possible.
❑ Diameter of pipe to be as large as

possible (ideal is l 120 mm ) and no
tight bends in pipe.
If long, rough exhaust-air pipes,
many pipe bends or smaller pipe
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.

21

32

600

170

133

287

313

195

250

Round pipes:

We recommend
Internal diameter at least. 120 mm.

Flact ducts must have an internal

cross-section that equates to that of
round pipes with a 100/120 mm internal
diameter
There should be no sharp bends.
l 100 mm approx.

0

78 cm

2

l 120 mm approx. 113 cm

2

If pipes have different diameters:
❑ Insert sealing strip.
For exhaust-air mode, ensure that

there is an adequate supply of fresh air.

Exhaust air flows upwards:

❑ Cut a hole in the top of the wall cupbo-

ard, including a groove for the mains
cable.
– Template

O

I

lis enclosed –.

mind. 30

115

80

185

120

512

243

269

90

250

32

280

598

280-443

For operating in exhaust-air mode, a
one-way flap should be mounted inside the
extractor hood unless there is already one
fitted in the outlet duct or wall ventilation
box.
If no one-way flap was enclosed with the
hood, it can be obtained from a specialist
retailer (see section on optional accessories
in the user instructions).

Installing the one-way flap:

1. Cut out the protective grid in the air-pipe