Appliance dimensions (fig. a), Safety clearances (fig. b), Preparing the units – Siemens LI18030 User Manual

Page 7: Notes, Create a cut-out for the exhaust-air pipe, Fitting the appliance, Screw the appliance to the fitted unit. (fig. 4), Removing the appliance, Disconnect the appliance from the power supply, Release the exhaust-air lines

Advertising
background image

Appliance dimensions (Fig. A)
Safety clearances (fig. B)

The minimum distance between the supporting surface for the

cooking equipment on the hob and the lowest part of the range

hood must be not less than 500 mm from electric cookers and

650 mm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a

greater distance, this must be adhered to.

Preparing the units

The fitted unit must be heat-resistant up to 90 °C. The stability of

the fitted unit must still be guaranteed after the cut-outs have

been removed.
Create the cut-out according to the installation drawing.
Remove any shavings after the cut-out work is complete.
Notes

Check the clearance between the intermediate floor and the

lower edge of the unit (see drawing).

Use the enclosed template for drilling the holes and creating

the cut-out.

1.

Place the template on the underside of the intermediate floor.

Drill the holes. (fig. 1)

2.

Create a cut-out for the exhaust-air pipe:
Exhaust-air opening above the fitted unit (fig. 2)

Exhaust-air opening behind the fitted unit (fig. 3)

Fitting the appliance

1.

Screw the appliance to the fitted unit. (fig. 4)

2.

Pull out the filter drawer until it is flush with the front edge of the

fitted unit. (fig. 5)

3.

Take out the metal grease filter. Slide the stop forward until it

rests against the filter drawer. In this position, fasten the stop

in place.

Removing the appliance

1.

Disconnect the appliance from the power supply.

2.

Release the exhaust-air lines.

3.

Loosen the screw connections with the unit.

4.

Remove the appliance.

Connecting the appliance (fig. 6)

Notes

For exhaust-air operation, a backflow flap should be fitted. If a

backflow flap has not been included with the appliance, it can

be obtained from a specialist retailer.

If the exhaust air is conveyed through the outer wall, a

telescopic wall box should be used.

Connecting the air extractor
Note:
If using an aluminium pipe, smooth the connection area

beforehand.

1.

Attach the air extractor pipe directly to the air-pipe connector.

2.

Connect to air extractor opening.

3.

Seal the joints appropriately.

Connect the power supply

1.

Plug the mains plug into the earthed socket.

2.

If a fixed connection is required, please follow the instructions

in the Electrical Connection section.

Advertising