Intermittent ventilation starts automatically. The display
switches back to idle state after the set time has elapsed.

The saturation of the grease filters can be queried via the
Information button. To do this, the extractor hood must be
switched on.

Press the

tbutton.

The saturation display of the grease filters can be reset even
before 100 % is reached.

1. Press the

t button again. The settings area is lit.

2. Using the rotary selector, set the saturation display to 0 %.

If the

t button is lit and a signal sounds when the extractor

hood has been switched off, the grease filters are 100%
saturated.

1. Clean the grease filters or replace the activated carbon

filter.

2. Set the indicator to “yes”.

3. Acknowledge the input by pressing the

t button.

Saturation displays
Grease filters

NOTE

Operation

Grease filter saturtd:
60%

Carbon filter saturtd:
50%

Information

Fettfilter gereinigt?
nein

Grease filter cleaned?
yes

Carbon filter replacd?
no