Sources, EQs and Amplifiers

Speakers

Note that the front amps and speakers
have matching group numbers as do
the rear amps and speakers. As a rule,
related amps and speakers have match-
ing group numbers; this determines
how the 902 Control Panel, if used,
handles Volume Compensation of the
products in these Groups. Figure 15
shows how the 902/903 Control Panel
would arrange these product groups on
its Product Group display windows.

B. Determine the Module ID settings.

Number the modules in each group to
put the products in the desired order in
the group. Use the following table for
the appropriate module ID setting for
each module.

FRONT AMP

FRONT SPEAKERS

REAR AMP

REAR SPEAKERS

ATTEN.

LEVEL

(STORE)

EQUAL VOLUME COMPARISON

ATTENUATION / SPL

DECIBELS

MUTE

(ADJUST)

P-NOISE AUTO-CAL

Theft Alert

SilenTouch

1

2

3

4

5

6

7

8

9

0

A

B

C

SECURE

ON / SPL

SUB AMP

SOURCES

PROCESSOR/EQ

SUBWOOFERS

ASD

å Demonstration Network

Patents Pending

Model 902 Control Panel

Figure 15. This is how product groups appear on the 902 Control Panel.

The display shows which product in each group is selected.

Switching

Addressing

Set the MODULE ID to:

Addressing

Set the MODULE ID to:

Modules

Sequence for

Sequence for

910, 922,

Product

slide

rotary

932

slide

rotary

958, 942Positions

switch

switch

Product Grps

switch

switch

1st module:

1 - 4

0 - 9

0

1 - 8

0 - 9

0

2nd module :

5 - 8

0 - 9

1

9 - 16

0 - 9

1

etc...

9 - 12 0 - 9

2

17 - 2

4

0 - 9

2

13 - 16

0 - 9

3

25 - 32

0 - 9

3

17 - 20

0 - 9

4

33 - 40

0 - 9

4

21 - 24

0 - 9

5

41 - 48

0 - 9

5

25 - 28

0 - 9

6

49 - 56

0 - 9

6

29 - 32

0 - 9

7

57 - 64

0 - 9

7

33 - 36

0 - 9

8

65 - 720 - 9

8

37 - 40

0 - 9

9

73 - 80

0 - 9

9

41 - 44

10 - 19

0

81 - 88

10 - 19

0

45 - 48

10 - 19

1

89 - 96

10 - 19

1

49 - 52 10 - 19

2

97 -99

10 - 19

2

53 - 56

10 - 19

3

57 - 60

10 - 19

4

61 - 64

10 - 19

5

65 - 68

10 - 19

6

69 - 72 10 - 19

7

73 - 76

10 - 19

8

77 - 80

10 - 19

9

81 - 84

20 - 29*

0

85 - 88

20 - 29*

1

89 - 92

20 - 29*

2

93 - 96

20 - 29*

3

97 - 99

20 - 29*

4

How to Use These Tables

Read accross from left to right. For the 1st
module’s
addressing sequence (products
one through four) set the MODULE ID to
0 - 9” on the slide switch, and “0” on the
rotary switch.

* Contact the factory if this address is needed.