Controller Installation

007-5510-002

13

2.2.3

Connecting the Controller

To set up the disk enclosures and connect them to the controller, do the following.

1.

There are 10 disk channels on the controller. They correspond with disk ports. The disk ports are
labeled as follows (Figure 2–1

)

:

DISK A = Channel A

DISK B = Channel B

DISK C = Channel C

DISK D = Channel D

DISK E = Channel E

DISK F = Channel F

DISK G = Channel G

DISK H = Channel H

DISK P = Channel P (parity)
DISK S = Channel S (spare)

Using the 10 copper SAS cables provided, connect these disk ports to your ten disk channels.

Figure 2–1

I/O Connectors

2.

Each controller supports up to four host connections. You may connect more than four client
systems to the controller using switches and you can restrict user access to the LUNs (as described
in Section 2.3 "Configuring the Controller" of this guide).

The Host ports are numbered 1 through 4 as shown in Figure 2–1. Connect your host system(s) or
switches to these ports. For FC-8 models, ensure that the latches on the transceivers are engaged.

2.2.4

Selecting SAS- ID for Your Drives

NOTE : The controller uses a select ID of 1.

2.2.5

Laying Out your Storage Drives

Tiers, or RAID groups, are the basic building blocks of the controller. A tier can be catalogued as 8+1
or 8+2. In 8+1 mode, a tier contains 10 drives—eight (8) data drives (Channels A through H), one parity
drive (Channel P), and one optional spare drive (Channel S). In 8+2 mode, a tier contains 10 drives—
eight (8) data drives (Channels A through H) and two parity drives (Channel P and S).

The controller can manage up to 120 tiers.

P

S

P

S

G

H

G

H

A

B

A

B

E

F

E

F

C

D

C

D

DISK CHANNELS

AC

FAIL

SYSTEM

STATUS

CTRL

STATUS

TEMP

STATUS

DISK

STATUS

DC

STATUS

FAN

STATUS

TEST

STATUS

ACT

HOST 1/2

CLI

HOST 1

HOST 2

1

2

STATUS

ACT

HOST 3/4

CLI

HOST 3

HOST 4

3

4

1/2

TEST

PLACE PIN HERE

LINK
ACT

MUTE

AC

FAIL

ACT

LINK

ACT

LINK

TELNET

ALARM

SILENCE

CLI

COM

LINK

Host port 3

Host port 1

Host port 4

Host port 2

Disk ports