Aprilaire 600 User Manual

Page 6

Advertising
background image

- 8 -

- 9 -

Your Aprilaire humidifier is controlled by a Manual Humidifier Control (see
Figure C). The Manual Humidifier Control is installed either in the cold air
return duct or on an interior wall of the home. With the Manual Humidifier
Control, it is important to anticipate a drop in outdoor temperature and reduce
the setting accordingly to avoid excessive condensation, just as with the
Digital Humidifier Control installed in Manual Mode (see page 6).

To determine the indoor RH, slowly turn the knob clockwise and counterclockwise
and listen for 2 clicks. The indoor RH is within the range of the 2 clicks.

OPERATING INSTRUCTIONS –
MODELS 350, 360, 400M, 500M, 600M & 700M

Set the knob to “Test/Reset”, make sure that the water saddle valve is open
and that there is electricity to the humidifier. The HVAC fan must be running
for the humidifier to function. Note: Turning the knob to “Test/Reset” resets
the “Change Water Panel” timer. The humidifier will only operate for 1
minute in test mode. (Model 400 and 400M: Floats must be down for the
solenoid valve to allow water flow.) Reduce the Humidifier Control setting
to the recommended inside RH, depending on the outside temperature. DO
NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE.

Set the knob to the highest setting, make sure that the water saddle valve is
open and that there is electricity to the humidifier. The HVAC system must
be operating for the humidifier to function. Confirm that the solenoid valve is
energized and water is flowing into the humidifier. Return control knob to
desired setting.

CHECK THE HUMIDIFIER OPERATION

DIGITAL HUMIDIFIER CONTROL

MANUAL HUMIDIFIER CONTROL

FIGURE C – Manual Humidifier Control

90-1237

TABLE 3 – Operation Guide

Condition

Solution

Condensation on windows.

Reduce the setting on the control dial by
1 increment.

Lack of humidity.

Increase the setting on the control dial by
1 increment. If the Humidifier Control is
already at the maximum setting of “7”, set
the Blower Activation Switch to “ON”. The
humidifier should be plumbed to hot water
when using the Blower Activation feature.

Humidifier does not operate.
(Solenoid does not “click”
when control is moved to
“Test/Reset” position.)

Turn dial to “Test/Reset”. Make certain
HVAC blower is operating. If unit still does
not operate, consult a heating contractor.

Humidifier won’t shut off.

Turn dial to “Off”. If unit continues to
operate, consult a heating contractor.

Test mode.

System operation is checked by setting
the knob to “Test/Reset”. Make certain
HVAC blower is operating. Humidifier will
operate for one minute. NOTE: Placing the
knob in “Test/Reset” resets the Water
Panel change timer.

Red “Call Dealer for Service”
light flashes (Figure A).

Note the error code on the display (E1, E2,
E3 or E4) and call your heating and air
conditioning dealer.

Yellow “Change Water Panel”
light flashes (Figure A).

Refer to the Annual Maintenance section
(page 11) for instructions on changing
the Water Panel or call your heating and
air conditioning dealer for service. After
the Water Panel is replaced, turn the
Control knob to the “Test/Reset”
position until the green “Humidifier On”
light flashes, to reset the Water Panel
change timer.

Advertising
This manual is related to the following products: