Operation:

Before each use: Always use a clean pre-fi lter bag when operating the machine.

If necessary, unscrew the stainless steel fi lter at the bottom of the recovery tank and clean it. Also make sure the

ball

fl oat in the recovery tank is clean.

• Attach a 3/4” garden hose to the dump pump outlet fi tting on the dump pump on the back of the base of the

machine.

Refer to illustration below.

• Run the other end of the hose into a drain.

• Turn ON the dump pump switch (switch is located on the switch panel on the top of the machine).

NOTE: the dump pump is ‘self-priming.’ You should see water start to fl ow within 30 seconds of the

pump turning on. If water does not begin to fl ow, check the fi lter to see if it is plugged with debris.
After each job: run clear water though the dump pump to wash out any chemical residue.

Remove and clean both the pre-fi lter bag and the stainless steel fi lter in the bottom of the tank. Reinstall the fi lter
once it is clean. Clean and empty the recovery tank

.

AUTO-DUMP

DANGER: always unplug the King Cobra from the electrical outlet(s) before

cleaning or maintaining. Certain internal components are electrically live,

even with switches in their OFF position.

Dump

Pump

Drain Hose

AUTO-DUMP

Power

Prime

Hose

DANGER: DO NOT USE SOLVENTS, OR ANY CHEMICALS THAT MAY BE

FLAMMABLE, EXPLOSIVE OR COMBUSTIBLE.

CAUTION: always use a defoamer in the recovery tank to prevent water or

foam from entering the vacuum motor.

Dump Hose