INSTALLATION SUMMARY

Note: More detailed instructions can be found in Excella’s
Installation and Operation Manual
(P/N 99875310).

The following is a summary of the major installation steps for
Excella:
1. Unpack Excella.
2. Install ink cartridge (the cartridge is shipped uninstalled).
3. Insert API/Demo CD in drive and install the Demo software.
4. Connect interface cable (USB or Ethernet) and power cable to

Excella.

5. Connect power cord to AC wall outlet.
6. Connect interface cable to PC.
7. Depending on your interface, continue with USB

INSTALLATION or ETHERNET INSTALLATION below.

USB INSTALLATION

The following is a summary of the installation steps for Excella
with a USB interface:
1. Ensure the API/Demo CD is inserted in the drive.
2. When the PC detects the new USB device, follow the

instruction wizard instructions.

3. When prompted, point to the CD as the source for the drivers.
4. After the drivers have been successfully installed, run the

“ExcellaUSBConfig” utility. On the PC, this utility can be found
on the folder: C:\Program Files\MagTek\Excella Demo.

5. For “Excella Device” select the USB Device ID

shown. For example, the default USB ID is “USB\
VID_0801&PID_2230\123”.

6. For “Excella Device(s) in MICRDEV.INI file”, choose the default

“EXCELLA_USB”.

7. For “IP Address(PC Side)”, use the default address or enter a

new address like 192.168.x.y (NOTE: “x” and “y” are numbers
between 2-254; pick “x” to avoid IP address conflicts).

8. For “IP Address (Device Side), use the default address or

enter a new address like 192.168.x.z. (NOTE: “x” and “z” are
numbers between 2-254; “x” must be the same as in step 7;
“z” must be different than “y” in step 7).

9. For “Subnet Mask”, enter a new Subnet Mask or use the

default: 255.255.255.0.

10. Click on “Apply”.
11. Click on “OK” and close the utility.

ETHERNET INSTALLATION

Excella is a web appliance and it offers several functions and
features in a built-in Web page accessible through a Web browser.
For example, if Excella’s default Ethernet device IP address is
192.168.10.100, type the “http://192.168.10.100” in your web
browser to access Excella’s web page.

On the main menu, the Configuration page offer options to setup
the Network and Ethernet configurations. Additionally, an option is
provided to save and restore device configurations.

EXCELLA OPERATION GUIDE

LED INDICATORS

The LED indicators are shown in Figure 5. All three LEDs are able

to show three colors: green, red, or amber. Each LED indicator has

been assigned a specific reporting function (see Table 1 below):

• Front LED: reports MICR read status

• Middle LED: reports path status

• Rear LED: reports unit status

Front LED

(MICR status)

Middle LED

(Path status)

Rear LED

(Unit status)

Description

Amber

Amber

Amber

Unit is initializing

Green

Green

Green

Power on, everything is OK

X

X

Flash Amber

Initializing network connection

Flash Red

X

X

After check read: MICR read error

Flash Green

X

X

After check read: good MICR read

Flash Red/Green

X

X

MICR noise detected (if enabled): relocate unit

X

Amber

X

Left or right access door unlatched (if feature is

installed): close and latch access guides

X

Flash Red

X

Paper jam: remove jam and hit operator button

to clear