Page 13

SPECIFICATIONS

ELECTRICAL

Input

Voltage

120VAC +12%, -25%
(without Battery discharge)

Power Factor Corrected

IAW MIL STD. 1399 Sec. 300

Frequency

45 to 65Hz

Current 7.2

A

Output

Voltage

120VAC

± 3%

Frequency

50Hz / 60Hz (software select)
Line Sync (software select)

Current 8.3

A

Crest Factor Ratio
(Non-linear load and
less than 5% THD) Typical

@50% Load Up to 4.8:1
@75% Load Up to 3.2:1
@100% Load Up to 2.4:1

Total Harmonic Distortion (THD)

3% Typ; 5% Max.
(@100% Non-linear load)

Dynamic Response

±4% for 100% Step Load Change,
0.5 Millisecond Recovery Time

Overload

110% for 10 Minutes;
200% for 0.5 Seconds

Efficiency (UPS)

85-87% Typical

UPS Protection

Input and Output Short Circuit;
Input and Output Overload;
Excessive Battery Discharge

ENVIRONMENTAL

Operating Temperature

-40

o

C(-40

o

F) to +74

o

C(+165

o

F)

Humidity

0% to 95% Non-condensing

Altitude

Sea Level to 10,000 Feet

Audible Noise

46 dBA at Five Feet

MECHANICAL

Input

NEMA 5-15P Plug w/6’ Cord

Output (Qty.)

(4) NEMA Type 5-15R Outlets

Cooling

Low Velocity, Forced Air

Dimensions: In. (mm)

3.5 (89)x19.0 (483)x18.0 (457)

Weight: Lbs. (Kg)
HxWxD

30 (13.5)

DESIGN

Standard Features

Power Factor Corrected, Digital

Regenerative

™ On-Line, Sinewave

Inverter Powers Load Continuously
Extended Brownout Protection
Designed for Non-linear Loads
Continuous Operation on

-25%,+12% Line

Automatic Bypass
RS232 Data Interface
Software Selectable Output

Frequency

AC Output Switch
Auxiliary Battery Connector
Rear Mounted Ground Stud
Optional SNMP Interface

Specifications

UL 1778, CUL, FCC Class A,
IEEE 587/ANSI C62.41,
IEC 555 @ 120VAC

MTBF

In Excess of 100,000 Hours

Typical Recharge Time to
85% Capacity at 100% Load

8 Hours

CONTROLS AND INDICATORS

Visual Indicators

Sequenced LEDs

Single LED

Battery Level, Load Level

AC Input, Inverter On, Load On
Summary Alarm, Alarm Silence,
Cold Start,

Front Panel Controls

Power On, Cold Start
Alarm Silence, Battery Test
AC Output On/Off

Audible Alarms

Utility Interrupt, Inverter Failure
Overload, Low Battery

RS232 Data Interface (DB-
9F)

Full Interactive, Remote Computer
Monitoring and Control of UPS
Functions.

Compatible with Systems
Enhancement

TM

UPS Monitor &

Control Software

Open-Collector (DB-9F)

Allows Alarm Function Monitoring

Optional SNMP Interface

(RJ45 or BNC)

Allows Full Control and Monitoring
Over Network Connection.

Specifications subject to change without notice.