Page 9, Model cph, Model ce – Coates PHS SERIES 54 & 480V THREE PHASE User Manual

Page 9

Advertising
background image

TB1 FOR REMOTE TEMPERATURE

CONTROL (IF USED).

CR7

CR7

GROUND

POOL

GROUND

ENCLOSURE

TERMINAL

HEATER GROUND

SEE INSTRUCTION MANUAL FOR COMPONENT

SINGLE PHASE

208V – 24 & 30kW

240V – 24 & 30kW

2.

CO

IL

CO

IL

IDENTIFICATION.

3.

ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.

B = BLACK

R = RED

LEGEND;

4.

W = WHITE

HEATING ELEMENTS

PL1 "

E

LE

MEN

T"

MODEL CPH

1BC2430H

1.

CR7

CO

IL

W

W

R

B

R

B

W

W

R

B

R

B

#8

#8

#8

#8

#8

#8

#10

#10

#10

F1

F1

F1

F1

F1

F1

CR7

COI

L

#10

#10

#10

#10

#10

#10

K7

3

1

TIMER

#2

BRASS

#1

COPPER

#3

ALUMINUM

1
23

4

NO

CO

M

K8

F5

F5

FLOW

RS2

TS1

PL4

"R

ESET”

PL2

"FLOW"

J4

J3

TS3

J1

J2

AC

AC

C

NO

J9

B W R

TEMP

ISOLATED

BUS

TB1 FOR REMOTE TEMPERATURE

CONTROL (IF USED).

FLOW SWITCH

CR7

CR7

GROUND

POOL

GROUND

ENCLOSURE

TERMINAL

HEATER GROUND

SEE INSTRUCTION MANUAL FOR COMPONENT

SINGLE PHASE

208V – 12, 15 & 18kW

240V – 12, 15 & 18kW

3.

CO

IL

COI

L

IDENTIFICATION.

4.

ALL WIRING TO BE 105°C INSULATED, MINIMUM.

CONTROL CIRCUIT WIRING; 14 AWG.

POWER CIRCUIT WIRING; AS NOTED.

B = BLACK

R = RED

LEGEND;

5.

W = WHITE

HEATING ELEMENTS

PL1 "

E

LE

MEN

T"

MODEL CE

F5

F5

6. HEATING ELEMENT QTY/RATING;

12kW = 2 @ 6kW

15kW = 1 @ 6kW & 1 @ 9kW

18kW = 2 @ 9kW

1BC1218G

1

2

CR7

COI

L

W

W

R

B

R

B

W

W

R

B

R

B

#8

#8

#8

#8

#8

#8

#8

#8

#8

#8

#8

#8

#10

#10

#10

#10

#10

#10

F1

F1

F1

F1

F1

F1

#2

BRASS

#1

COPPER

#3

ALUMINUM

1
23

4

NO

CO

M

K8

FLOW

RS2

TS1

PL

4 "R

ES

ET

PL2

"FLOW"

J4

J3

TS3

J1

J2

AC

AC

C

NO

J9

B W R

TEMP

ISOLATED

BUS

Page 9

Advertising
This manual is related to the following products: