background image

Quick Start Function Instructions for
GC35 Heavy Duty Digital Pressure Sensor
Version 1.0 6/06/09

(See Complete I&M Manual for Further Detail)

© 2010 Ashcroft Inc., 250 East Main St., Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0499,
www.ashcroft.com All sales subject to standard terms and conditions of sale.
8/10 I&M011-10182-GC35 Ver. 6.03 Rev. B

Collector/switch 1
LED operation
indicator (OUT 2)

4 Digit, 8mm
LED display

UP key

DOWN key

MODE key

Setting mode
LED operation
indicator (SET)

Collector/switch 1
LED operation indicator
(OUT 1)

Function

Display of pressure, linear scaling

Change to/from switch setting modes and
product’s settings

Change selections / decrease set values

Change selections / increase set values

Indicates switch state. LED indicator will be ON
when switch is activated

Identifies that the switch setting has been
performed

Designation

Measurement Display

Mode Key

MODE

Down Key #

Up Key $

Collector / Switch LED
Operation Indicator
(OUT1)/(OUT2)

Switch Setting Mode LED
Operation Indicator (SET)

DISPLAY OVERVIEW

2.00˝

3´.00˝

Note: Unit requires M12 mating connector p/n# 611C175-03
(standard 3 foot length) – see below.