Matrix Orbital GLK12232-25-SM User Manual
Page 12
Advertising
Power/Connector
Regular GLK12232-25-SM input
-V option input
Vcc
+5V only
9-15V
+5V
+5V only
N/C
+12V
N/C
+12V
NOTE
+12V is nominal for the -V but supply of 9-15V is acceptable
Figure 11: Power and Data Configuration
To power up and communicate with a GLK12232-25-SM (standard or wide voltage options), the users
have two options for connections:
• power and data connections using the Power/Data Connector of the GLK12232-25-SM (supply Vcc
with the proper voltage)
• power connections using the Floppy Power connector and data (RX/TX) and ground using the Power/Data
connector
NOTES
• A common ground should be used at all times
• Each module ordered has specific voltages and cannot be interchanged
Matrix Orbital
GLK12232-25-SM
7
Advertising