Power/Connector

Regular GLK12232-25-SM input

-V option input

Vcc

+5V only

9-15V

+5V

+5V only

N/C

+12V

N/C

+12V

NOTE

+12V is nominal for the -V but supply of 9-15V is acceptable

Figure 11: Power and Data Configuration

To power up and communicate with a GLK12232-25-SM (standard or wide voltage options), the users

have two options for connections:

• power and data connections using the Power/Data Connector of the GLK12232-25-SM (supply Vcc

with the proper voltage)

• power connections using the Floppy Power connector and data (RX/TX) and ground using the Power/Data

connector

NOTES

• A common ground should be used at all times
• Each module ordered has specific voltages and cannot be interchanged