Features, Communication/power connector (elk204-7t), Led indicators – Matrix Orbital EGLK19264A-7T User Manual

Page 7: Keypad input, Manual override

Advertising
background image

4

Features

Communication/Power Connector (ELK204-7T)

The ELK Series comes with a simple four pin TE
282834-4 style terminal block to fulfill both
communication and power needs. Voltage is
applied through pins one and four while pins two
and three are reserved for serial or I

2

C transmission.

This versatile header can be connected to a variety
of cables for a simple interface to any host.

Figure 5: Com/Power

Connector

Table 1: Com/Power Pinout

Pin Function

1

Gnd

2

Tx (SDA)

3

Rx (SCL)

4

Vcc

Extended Communication/Power Connector (EGLK19264A-7T)

The EGLK Series comes with a simple six pin
TE 282834-6 style terminal block to fulfill both
communication and power needs. Voltage is
applied through pins one and four while pins
two and three are reserved for serial or I

2

C

transmission. Pins five and six can be used for
optional hardware flow control using a serial
protocol only.

Figure 6: Ext C/P Connector

Table 2: E C/P Pinout

Pin Function

1

RTS

2

CTS

3

Gnd

4

Tx (SDA)

5

Rx (SCL)

6

Vcc

LED Indicators

The Enclosure Series has 6 General Purpose
Outputs which control 3 bi-colour LEDs. Red,
green, and orange-yellow colours can be
created using these software controlled GPOs.
Odd numbered GPOs control red while even
numbers switch the green aspects of the LEDs,
as shown in the table to the right.

Figure 7: LED Location

Table 3: LED Output

Colour GPO

O

GPO

E

Yellow

0

0

Green

0

1

Red

1

0

Off

1

1

Keypad Input

The Enclosure Series includes a 7 key,
matrix style, embedded keypad and may
be configured to allow key presses to be
automatically transmitted or polled. The
keypad can also be configured for
typematic or auto-repeating key presses.
The keypad is scanned only when pressed
to reduce electrical noise and decrease
latency to ensure key input is received
quickly and correctly every time.

Figure 8: Key Down Values

Figure 9: Key Up Values

Manual Override

The Manual Override is
provided to allow the Enclosure
Series to be temporarily reset
to factory defaults.

1. Disconnect power from your display.
2. Hold down the bottom left button.
3. Reconnect power and wait for the start

screen before releasing the button.

4. Set and save all pertinent settings.

Parameter

Value

Backlight

255

Contrast

128

Baud Rate

19200

Table 4: Manual

Override Settings

Advertising