Matrix Orbital DD-DB1 LCD/VFD Dev Board User Manual

Page 27

Advertising
background image

4. General Purpose Output

4.1.General Purpose

Output Off

Dec

Hex
ASCII

254 86

FE 56

V

Number

Number
Number

Turns the specified GPO off. Will only affect onboard LEDs if LED enable is jumped.

Number

1 byte, GPO (1-6) to be turned off

4.2.General Purpose

Output On

Dec

Hex
ASCII

254 87

FE 57

W

Number

Number
Number

Turns the specified GPO on. Will only affect onboard LEDs if LED enable is jumped.

Number

1 byte, GPO (1-6) to be turned off

4.3.Set Startup

GPO State

Dec
Hex

254 195

FE C3

Number State
Number State

Sets the start up state of the specified GPO. Changes will only be seen on start up.

Number

1 byte, GPO (1-6) to be turned off

State

1 byte, 1 for ON or 0 for OFF

25