Technical data, Startup/additional information – Siemens DE1821415 User Manual

Page 9

Advertising
background image

9

en

VI.

Startup/additional information

The device is compliant to IEC 61000-3-12.

First start-up

Switch on the fuses.

Setting the temperature.

Starts rinsing: Open the warm water tap and allow water

to flow for at least 1 minute (flow-rate at least 6 litres per
minute). Only then (for safety reasons) will the appliance
begin to heat.

Tip: Should the appliance not start because of a reduced
flow-rate, remove the perlator, shower head or similar before
start and repeat the process.

Remove the flow-rate limiter (see Fig. A) with low water

pressure.

Explain the operation of the continuous-flow heater to

the user.

A

If the continuous-flow heater does not have sufficient
water flow due to low water line pressure in your do-
mestic plumbing system, remove the flow-rate limiter.

Technical data

DE 1113415

DE 1821415

DE 4151821

DE 2427415

DE 4152427

Rated output

[kW]

11.0
13.0

18
21

24
27

Rated voltage

[V]

400

400

400

Fuse protection

[A]

16 / 20

32

40

Minimum conductor cross-section

[mm

2

]

4

4

6

Warm water flow at rated output

with temperature increase from

12 °C to 38 °C

[l/min]

6.0
7.1

9.9
11.6

13.2
13.9

12 °C to 60 °C

[l/min]

3.8
3.3

5.4
6.3

7.2
7.6

Start-up flow

[l/min]

2.6

2.6

2.6

Start-up flow pressure *

[MPa (bar)]

0.025 (0.25)

0.025 (0.25)

0.025 (0.25)

Application area in water
specific electric resistance at 15 °C

[Ωcm]

≥ 1 300

≥ 1 300

≥ 1 300

Rated pressure

[MPa (bar)]

1.0 (10.0)

1.0 (10.0)

1.0 (10.0)

Maximum permissible supply temperature

[°C]

55

55

55

Maximum mains impedance at connection
point

[Ω]

≤ 0.244

≤ 0.244

≤ 0.244

* The pressure loss on the mixer must also be added

B

Priority circuit for the combination with electrical
storage heaters:
For operation with a priority circuit, a special load
shedding relay BZ 45L20 (special accessory) is re-
quired. Other existing load shedding relays, with the
exception of electronic load shedding relays, may
malfunction.

C

The control electronics must be coded when operated
with a load shedding relay.

D

Status display on the appliance

LED

Appliance status

Off

Off

Lights up

Ready

Slow flash (1/s)

Appliance is heating

Fast flash (4/s)

Desired water temperature
is not reached (water flow
too high for appliance
rating).

E

The filter upstream from the check valve in the cold
water supply inlet is clogged.
Remove the filter and either clean it or descale it.
See Figure E 1–3.

Advertising