Special accessories – Siemens DE2427415 User Manual

Page 16

Advertising
background image

10

en

Special accessories

Pipe kit

BZ 45U20: for use of the continuous-flow heater

as an under sink appliance

Priority switch (load shedding relay)

BZ 45L20:

for operation with a priority circuit

Mounting kit

BZ 45K23: for surface mount installation

Thermostatic premixer

BZ 45T20: for installation in the

domestic plumbing when using preheated water

Operation with prewarmed water (solar heated)

The continuous-flow heater can only heat prewarmed water
to a max. of 60 °C. If the cold water supply exceeds a tem-
perature of 55 °C, the water will not be warmed any further.

Important: The cold water supply temperature must not be
higher than 55 °C!

If the cold water supply exceeds a temperature of 60 °C, a
circuit breaker will trigger and shut the appliance off. There-
fore, the residential plumbing must be equipped with a ther-
mostatic premixer (e. g. special accessory

BZ 45T20) that will

limit the cold water supply temperature to a max. of 55 °C by
appropriately mixing in cold water.

G

1 2

A

472

99

115

236

20

100

332

42

388

Advertising
This manual is related to the following products: