33

Problem

Remedy

Possible cause

The interior lighting is
not working.

The bulb is faulty.

Replace the bulb:

1. Unplug the appliance from the

mains or switch off the circuit
breaker.

2. Remove the lamp cover, figure

(.

3. Change the bulb (replacement

bulb: 220-240 V alternating
current, E14 socket, see faulty
light for the wattage).

The refrigerating unit
switches on with
increasing frequency
and for longer
periods.

The chest lid is being
opened frequently.

Do not open the lid unnecessarily.

The ventilation
openings are
covered. Figure

*

Remove any obstructions.

The "alarm" indicator
(figure

"/3) lights up.

(it is too warm in the
appliance).

The chest lid is being
opened frequently.

Do not open the lid unnecessarily.

Lots of food has been
placed in the freezer.

Switch on SuperFreezing before
placing food in the freezer.

The ventilation
openings are
covered. Figure

*

Remove any obstructions.

The appliance is
beside a heat source.

Maintain the minimum distance or
use an insulating plate.

The green control
light (figure

"/4) is

not lit.

The appliance is
switched off.

Connect the mains plug.

Power failure; the
fuse protection has
been switched off;
the mains plug is not
firmly inserted.

Check whether there is power,
check the fuses.