Connecting the appliance, En 24, Electrical connection – Siemens GC24MAW30 User Manual

Page 24

Advertising
background image

en

24

Connecting the
appliance

After setting up the appliance, wait for at
least 1 hour before starting the
appliance up. The oil contained in the
compressor may have been displaced
into the refrigeration system during
transport.

Before starting the appliance up for the
first time, clean its interior (see section
"Cleaning the appliance").

Electrical connection

The socket must be near to the
appliance and easily accessible after the
appliance has been installed.

The appliance conforms to protection
class I. Connect the appliance to a
220-240 V/50 Hz alternating current
supply using a socket with protective
earthing conductor which has been
correctly installed. The socket must be
protected by a fuse with a rating of 10 A
to 16 A.

In the case of appliances operated
outside of Europe, check whether the
voltage and type of current specified
conform to the values of your electricity
grid. You will find this information on the
rating plate, figure

+.

!

Warning

The appliance must never be connected
up to an electronic energy-saving
socket.

Sinusoidal-commutated and
line-commutated inverters can be used
with our appliances. Line-commutated
inverters are used with photovoltaic
systems that are connected directly to
the national grid.
Sinusoidal-communicated inverters must
be used with standalone applications
(e.g. on ships or mountain huts) that do
not have a direct connection to the
national grid.