American Standard Whirlpool/Bathing Pool 2748.XXXW User Manual

Installation instructions, Whirlpool/bathing pool 2748.xxxw series, Town square® 5' x 42

Advertising
background image

INSTALLATION INSTRUCTIONS

753026-100 Rev. G

© American Standard Inc. 2007
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

HIGH GLOSS ACRYLIC

SHOWN LESS ALL FITTINGS

TOWN SQUARE®

5' x 42"™

WHIRLPOOL/BATHING POOL

2748.XXXW SERIES

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

THANK YOU...

for selecting an American Standard bath. Your

new bath is shipped to you after careful

inspection. The whirlpool version is completely

assembled with pump, motor, and system piping.

All you need to finish the installation are your

selected fittings and electrical connections for a

whirlpool. To insure maximum performance and

pleasure from this product, please follow the

instructions and cautions.

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately. After inspection and during installation, protect the bath from construction damage. After installation, and
before enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the
safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or
piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing
materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess
installations). If installing American Standard 2555.901 "Town Square" deck mount bath filler, please refer to hole
drilling location above.

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.

List of Optional Components (not included):
• Tile Bead Kit (P/N 751755-200)
• 5 Foot Apron 9460.018
• Safe-T-Heater 9075.120*

List of Required Components (not included):
• Drain 1594.170
• Bath Filler

List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun

Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout

C/L

FOR SPOUT

& VALVES

FOR HAND
SPRAY

FITTINGS
DECK

EDGE OF
FITTINGS

DECK

29-7/8

(759mm)

TO END

OF TUB

1-1/2

(38mm)

1-1/2

(38mm)

1-1/2

(38mm)

4-1/2

(114mm)

2-1/2

(64mm)

4-1/2

(114mm)

5

(127mm)

DRAIN

HOLE DRILLING LOCATION FOR AMERICAN STANDARD "TOWN SQUARE"
DECK MOUNT BATH FILLER WITH PERSONAL SHOWER, MODEL #2555.901 ONLY

SAFE-T-HEATER
REMOVABLE
BLANK

59-1/2"

(1511mm)

INTEGRAL
FITTING DECK
2-1/2" X 14"
(64 X 356mm)

29-7/8"

(759mm)

41-5/8"

(1057mm)

ON/OFF
SWITCH

SUCTION

OUTLINE OF CUTOUT
58-1/4" X 40-1/4"
(1480 X 1022mm)

PROVIDE ACCESS

TO PUMP FOR

SERVICE ON ALL

INSTALLATIONS

C/L OF
DRAIN
OUTLET

FLOOR CUTOUT

5" X 12"

(127 X 305mm)

3/4"
(19mm)

14-1/2"

(368mm)

5-1/4"
(133mm)

JETS (6)

3"

(76mm)

OUTLINE OF

SKID RESISTANT

SURFACE

LEVELING STRINGER

(NOT FOR SUPPORT)

1-1/2" N.P.T.
THREADS

2"

(51mm)

5-3/4"

(146mm)

C/L OF
OVERFLOW

21"

(533mm)

23"

(584mm)

ROUGH

FLOOR

INTEGRAL
FEET
SUPPORT

1-1/2" O.D.
TAILPIECE

3/4"
(19mm)

3-1/8"

(79mm)

PUMP

EDGE OF
FLOOR
CUTOUT

PUMP

GENERAL SPECIFICATIONS FOR 2742 WHIRLPOOL

71-1/2 x 41-3/4 x 22 In. (1816 x 1060 x 559mm)

115 Lbs. (52 Kg.)

690 Lbs. (313 Kg.)

69 Gal. (261 L)
60 Gal. (227 L)

41 x 21-1/2 In. (1041 x 546mm)
62 x 31-1/2 In. (1574 x 800mm)

14-1/4 In. (362mm)

33 Lbs./Sq.Ft. (163 Kgs./Sq.m)

27.8
55.7

2.1 HP, 14.4 AMPS ,120V.

WHIRLPOOL PUMP

WHIRLPOOL ELECTRICAL SPECIFICATIONS

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

Advertising