Installation, Electrical installation, Electrical connection – Siemens 30inc iSlide Single Oven User Manual

Page 8

Advertising
background image

English 6

Installation

Electrical Installation

All model ovens on the front cover are dual rated, designed to be connected to
either 208/240V AC, 60 Hz, 4 wire, single-phase power supply.

The electrical supply should be a 4-wire single-phase AC. Install a suitable conduit
box (not furnished).

Important: Local Codes may vary, installation, electrical connections and
grounding must comply with all applicable local codes.

If local codes permit grounding through the electrical supply neutral, connect both
the white neutral wire and the bare ground wire from the oven to the white neutral
electrical supply wire.

Electrical Connection

The four-wire connection is preferred, but where local codes permit, the three wire
connection is also acceptable.

Four-wire Connection

Connect the red oven wire to the red electrical supply wire (hot wire).

Connect the black oven wire to the black electrical supply wire (hot wire).

Connect the white neutral oven wire to the white neutral (not bare ground)
electrical supply wire.

Connect the bare ground oven wire to the bare ground electrical supply wire.

Model

Circuit Required

208V, 60 Hz

240V, 60 Hz

HB30S51UC

30 AMP

30 AMP

HB30D51UC

40 or 50 Amp circuit. Refer to local electrical codes
for de-rating requirements.

Advertising
This manual is related to the following products: