12

There are 4 address codes on both remote the paging console and the extension keypad which are used to identify
these.

Only one address code switch of each dip switch can be placed in the downward position.If any of the dip switches are
set at different addresses to those shown above, the console will not operate.

Extension keypad Remote paging Console Connection is made through the supplied 10P IDE cable. Once either two
or three QTEP extension panels are connected, the operation of paging announcements is the same as described
previously for individual zone paging or all call actions.

Please Note:

Power Supply

Connection Between Remote Paging Console & Extension Keypad

The remote paging console is powered by the Matrix through the RJ45 communication port when the communication
distance is < 50 meters. An extra DC 24V po wer input is equipped on the back part of the paging console to supply
power when the communication distance is longer than 50 meters.

The IDE communication cable is used to provide connection between the remote paging console and the extension
keypad as well as between two extension keypads.

Connection Through
10P IDE Cable

Extension Keypad

Remote Paging Console

Extension Keypad Dip Switch Setting

Extension Keypad 1

Extension Keypad 3

Extension Keypad 2