LBL Lighting Fusion Jack 4" Round Dome Flush Canopy w/Vault Adapter LED User Manual

Fusion jack, Use minimum 90°c supply conductors. 1a, Installation instructions for

Advertising
background image

Fusion Jack

CAUTION - RISK OF FIRE

This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.

Use minimum 90°c supply conductors.

1A

1

2

1

Installation Instructions for

Fusion Jack 4" Round Dome Canopy
for Vaulted Ceilings

1.1

CK001B-FJV-_

980FSJDMCV

G

P

I

:

ENERAL

RODUCT NFORMATION

This product is ETL listed and suitable only for dry locations and

approved for use at any height above the finished floor.

This product can be dimmed with a low-voltage electronic dimmer.

The mounting surface must not be greater than 40 degrees from

horizontal.

BACKPLATE

FLAT HEAD
SCREW

DOME
CANOPY

Loosen the two flat head screws to remove the backplate from

the dome canopy.

Connect the green transformer wire and backplate wire to a
suitable ground in accordance with local electrical codes.

Connect the white transformer wire to the neutral power line
wire with a wire nut.

Connect the black transformer wire to the hot power line
wire with a wire nut.

Place all wires and wire nut connections into the electrical box.

Mount the backplate to the electrical box with the two #8-32
round head screws.

Replace the dome cover onto the backplate. Replace and
tighten the two flat head screws.

POWER LINE WIRES

VAULTED

CEILING

ELECTRICAL
BOX

3

4

6

7

5

6

7

6

7

3

4

2

Advertising