I2c communication does not work, My usb disk is not detected / does not work, 3 additional support – Aero-Flex GAISLER GR-LEON4-ITX User Manual

Page 32

Advertising
background image

32

GR-LEON4-ITX Development Board

Quick Start Guide

There is no known workaround for this issue and the LEON4-ASIC-DEMO device cannot be
used in a system where it will be accessed by a master performing bursts over eight words in

length.

I

2

C communication does not work

Please make sure that the bus has pull-ups (see the GR-LEON4-ITX Board User Manual for
how to enable pull-ups).

My USB disk is not detected / does not work

The board may not be able to provide enough power for drives connected via USB. Try

connecting the device via a USB hub that has a power source.

How do I change the Ethernet Debug Link IP address in the delivered system?

The system is delivered pre-programmed with the bootloader U-boot. After system reset, U-
boot will initialize the system, which includes setting the Ethernet Debug Communication

Link's (EDCL) IP address. The address used by U-boot can be changed by attaching a USB
keyboard and pressing any key during the first seconds of system boot. U-boot will then

interrupt the boot process and show a prompt.
The IP address that U-boot will assign to the EDCL is stored in the variable greth_edcl_ip0.

To show the systems variables, issue the command:

=> printenv

To change the EDCL IP address to 172.16.0.24, issue the command:

=> setenv greth_edcl_ip0 172.16.0.24

To preserve the value after system reset the variable needs to be saved to SPI flash, this is

done with the command:

=> saveenv

It is also possible to change the EDCL IP address via GRMON, using the edcl command.

However, this will not affect the address used by U-boot after system reset.

6.3 Additional support

For customers with a support contract, or for issues where the board or device seem faulty,

please contact

[email protected]

.

© Aeroflex Gaisler AB

June 2010, Rev. 0.2