4 | SAMLEX AMERICA INC.

LED Display

The following LeD displays are available:
• Green LED (4) marked POWER. This LED will be lighted when the inverter is

in ON condition. When the inverter is in OFF condition, this LED will not be
lighted. This LeD shows that DC input is available to the inverter and that
the input section of the inverter is operating normally

• Red LED (2) marked OVER LOAD. When lighted, it indicates that the AC

output of the inverter has been shut down due to over load

• Red LED (3) marked OVER TEMP. When lighted, it indicates that the AC

output of the inverter has been shut down due to over temperature

ON/OFF Control
oN/off Push button (1) is used to switch oN and switch off the inverter.

Pinout Of Rj-12 / Rj-25 Modular jack
The pinout of the RJ-12 / RJ-25 Modular Jack (5) at the back of the unit is given
at fig. 2 below:

Fig. 2 Remote Control RC-15A - Pinout of Modular Jack RJ-12 / RJ-25

The standard numbering system of the pins of a Modular Jack, when looking
into the Jack, is from left to right. As the conductors of the cable are cross-
connected (rolled-over), the pinouts at the Modular Jack in the inverter will
be a mirror image of the pinout of the Modular Jack in the Remote Control as
shown below:

Pinout of Modular jack on

the Remote Control

1

Signal

Pinout of Modular

jack on the inverter

2

1

LED - “OVER LOAD”

6

2

Toggle

5

3

Ground / Common

4

4

Vbattery

3

5

LED - “POWER ON”

2

6

LED - “OVER TEMP”

1

1 2 3 4 5 6

LEGEND

LED - “Over Load”

Toggle

Ground

Vbattery

LED - “Power ON”

LED - “Over Temp”

1.

2.

3.

4.

5.

6.

Figure 2 Remote Control RC-15A; Pintout of Modular Jack RJ-12 / RJ-25

1. As shown in Figure 2
2. Mirror image of Remote Control Jack due to crossed-over /rolled over connection of conductors.