Media Technology Systems ION8.8 User Manual

Page 19

Advertising
background image

Page
19
of
31


Aug‐09

Note:
The
GUI
is
common
to
the
MTS
amplifier
line
and
there
will
be
many
amplifier

parameters
shown
in
the
screen.
However,
these
will
be
grayed
out
and
can
be
ignored.


These
will
not
be
referred
to
in
the
descriptions
below.


The
default
page
will
show
192.168.192.100,
as
this
is
the
factory
IP
address
set
in
the

GUI.
If
this
is
a
new
ION
then
simply
press
“Connect”.



Note:
Each
ION
will
attempt
to
obtain
an
IP
address
by
DHCP
on
power
up.
This
process

lasts
about
1
minute.
Until
the
DHCP
period
is
over,
it
will
not
be
possible
to
connect
to

the
ION
using
the
GUI.
If
the
ION
has
been
programmed
with
a
default
address,
then
it


will
not
follow
a
DHCP
process.


Also
note
that
the
internal
UART
interrupts
are
not
enabled
until
after
the
DHCP

process,
so
ION
parameters
cannot
be
changed
or
updated
during
the
DHCP
period.


NOTE:
many
pages,
or
sections
of
pages,
have
an
“UPDATE”
button.
If
changes
are
made

through
SNMP
or
TELNET,
rather
than
the
GUI,
these
changes
will
only
be
reflected
in

the
GUI
after
pressing
UPDATE.
Otherwise,
the
GUI
would
have
to
continuous
poll
every


setting
and
the
HMI
would
have
little
processing
time
left
over.


4.2.2 System
settings



Selecting
the
“System”
tab
will
open
the
page
shown
in
Figure 4-3
below.
The
settings

are
changed
as
follows:‐


Ethernet
IP
address:
This
can
be
changed
from
the
default
address
to
any

address.
Enter
the
new
address
and
press
“Set”.
Note:
once
the
IP
address
is


changed,
the
user
will
need
to
wait
approximately
20
seconds
for
the
application

to
reconnect,
or
they
can
restart
the
application
and
enter
the
new
address.


CobraNet™
IP
address:
As
CobraNet™
is
layer
2,
it
does
not
need
an
IP
address
to

pass
audio.
However,
for
programming
via
SNMP
the
default
CobraNet™
address


of
0.0.0.0
can
be
changed.
The
IP
address
set
using
the
GUI
is
persistent.


The
CobraNet™
firmware
revision
is
for
information
only.
There
is
no
setting.

New
firmware
should
be
loaded
using
CobraNet™
Discovery
(CNDISCO).



The
parameters
are
set
as
follows:


o

The
RS485
bridge
status
allows
the
user
to
switch
the
RS485
port

between
local/remote
ION
control
&
monitoring
or
serial
bridging.


o

The
RS485
address
refers
to
the
address
used
by
the
RS485
port
to

communicate
to
external
devices
(TBA).


o

The
RS485
Master/Slave
switch
allows
the
ION
to
be
slaved
to
a
host

processor
or
act
as
the
Master
controller
for
the
MTS
wall
panels
or
a

remote
MTS
ION
(TBA).



o

The
remote
MAC
address
refers
to
the
serial
bridging
channel
settings

described
in
the
Cirrus
Logic
PM25
document.


Please
note
that
the


remote
MAC
address
value
is
NOT
stored
in
presets
due
to
issues
with
the


Advertising
This manual is related to the following products: