Campbell Scientific CR10X Prompt Sheet User Manual

Cr10x instructions and parameters, Processing instructions, Option codes

Advertising
background image

INST.

01:

02:

03:

04:

05:

06:

07:

08:

09:

10:

11:

12:

13:

14:

1

VOLT (SE)

REPS

RANGE†

SE CHAN

LOC

MULT

OFFSET

2

VOLT (DIFF)

REPS

RANGE†

DIFF CHAN

LOC

MULT

OFFSET

3

PULSE

REPS

CHAN/PORT

CONFIG†

LOC

MULT

OFFSET

4

EX-DEL-SE

REPS

RANGE†

SE CHAN

EX CHAN†

DELAY 0.01 s

EXCIT mV

LOC

MULT

OFFSET

5

AC HALF BR

REPS

RANGE†

SE CHAN

EX CHAN†

EXCIT mV

LOC

MULT

OFFSET

6

FULL BR

REPS

RANGE†

DIFF CHAN

EX CHAN†

EXCIT mV

LOC

MULT

OFFSET

7

3W HALF BR

REPS

RANGE†

SE CHAN

EX CHAN†

EXCIT mV

LOC

MULT

OFFSET

8

EX-DEL-DIFF

REPS

RANGE†

DIFF CHAN

EX CHAN†

DELAY 0.01 s

EXCIT mV

LOC

MULT

OFFSET

9

FULL BR w/M EX

REPS

EX RANGE†

BR RANGE†

DIFF CHAN

EX CHAN†

EXCIT mV

LOC

MULT

OFFSET

10

BATT VOLT

LOC

11

TEMP (107)

REPS

SE CHAN

EX CHAN†

LOC

MULT

OFFSET

12

RH (207)

REPS

SE CHAN

EX CHAN†

TEMP LOC

RH LOC

MULT

OFFSET

13

TC TEMP (SE)

REPS

RANGE†

CHAN/LOC†

TC TYPE†

REF LOC

LOC

MULT

OFFSET

14

TC TEMP (DIFF)

REPS

RANGE†

CHAN/LOC†

TC TYPE†

REF LOC

LOC

MULT

OFFSET

15

PORT SERIAL I/O

REPS

CONFIG†

CTS/DELAY

PORT

OUT LOC

NO. LOC

T CHAR

MAX

IN DELAY

LOC

MULT

OFFSET

16

RTD TEMP

REPS

R/Ro LOC

LOC

MULT

OFFSET

17

INTERNAL TEMP

LOC

18

TIME

OPTION†

MOD/BY

LOC

19

SIGNATURE

LOC

20

PORT SET

8765†

4321†

21

PORT w/DURATION

PORT

LOC DELAY 0.01 s

22

EXCIT w/DEL

EX CHAN†

DEL w/ex.

DEL after ex.

EXCIT mV†

23

BURST MODE

NO. CHAN

RANGE†

IN CHAN

OPTION†

SCAN (ms)

SCANS (10

3

) SMPLS

TR LIM mV

EXCIT mV

LOC

MULT

OFFSET

24

CALIBRATION

LOC†

25

READ PORTS

MASK†

LOC

26

TIMER

LOC (0 resets timer)

27

PERIOD AVG (SE)

REPS

OPTION†

SE CHAN

NO CYC

LIM 0.01 s

LOC

MULT

OFFSET

28

VIB WIRE (SE)

REPS†

SE CHAN

EX CHAN

START F†

END F†

NO CYC

DEL 0.01 s

LOC

MULT

OFFSET

29

PS9104E

DIFF CHAN

EX CHAN

LOC

Enhanced Parameters (CSI parameters 4-23)†

100

TDR 1502B

See manual

101

SDM-INT8

ADDR

C:8765†

C:4321†

F:8765†

F:4321†

AVG OPT†

LOC

MULT

OFFSET

102

SDM-SW8A

REPS

ADDR

FUNCT†

CHAN

LOC

MULT

OFFSET

103

SDM-AO4

REPS

ADDR

LOC

104

SDM-CD16AC

REPS

ADDR

LOC

105

SDI-12 RECORDER

ADDR

CMD†

PORT

LOC

MULT

OFFSET

106

SDI-12 SENSOR

ADDR

TIME/VAL†

LOC

107

SDM CSAT3

REPS

ADDR

OPTION†

LOC

108

SDM UDG01

ADDR

TEMP LOC

LOC

MULT

OFFSET

109

SDMX50

ADDR

CHAN

110

SDM GROUP TRIGGER

113

SDM-SIO4

REPS

ADDR

MODE

COMMAND

1

ST

PAR

2

ND

PAR

VALUES/REP LOC

MULT

OFFSET

114

SET TIME

OPTION†

LOC

115

SDM BAUD

BIT PERIOD 10 µs

117

DATALOGGER ID

LOC

118

SDM CAN

ADDR

T.QUANTA

TSEG1

TSEG2

ID 0-10

ID 11-23

ID 24-28

DATA TYPES

START BIT

NO. BITS

NO. VALUES

LOC

MULT

OFFSET

119

TDR100

ADDR

OUTPUT†

MUX/PROBE† WAVFRM AV Vp

POINTS

C. LENGTH

W.LENGTH

P.LENGTH

P.OFFSET

LOC

MULT

OFFSET

130

STATUS MONITOR

OPTION†

LOC

131

EXTENDED VIB WIRE

REPS

RANGE†

SE CHAN

EX CHAN

START F

END F

SWEEP

NO. STEPS

D MEAS

CYCLES

D REPS

LOC

MULT

OFFSET

138

CS616 WATER CONTENT REPS

SE CHAN

PORT†

LOC

MULT

OFFSET

188

SDM-IO16

ADDR

COMMAND

1

ST

PAR†

2

ND

PAR†

3

RD

PAR†

4

TH

PAR†

C.LOC

LOC

MULT

OFFSET

1-14

RANGE codes:

Slow (2.72 ms integration time)

Fast (250 µs integration time)

60 Hz rejection

50 Hz rejection

Full scale range

0

10 20

30

Autorange

1

11 21

31

± 2.5 mV

2

12 22

32

± 7.5 mV

3

13 23

33

± 25 mV

4

14 24

34

± 250 mV

5

15 25

35

± 2500 mV

3

CONFIGuration codes:

To record all counts:

0 High frequency (-- 64 Hz reset)
1 Low level AC (-- 64 Hz reset)
2 Switch Closure
3 High frequency, 16-bit
4 Low level AC, 16-bit
4 Low level AC, 16-bit

Discard counts beyond execution Interval

1x (x = 0-4 from above)

Discard counts, output frequency (Hz)

2x (x = 0-4 from above)

4-10,12

EXcitation CHANnel codes:

0x Excite all reps with EX CHAN x
1x Increment EX CHAN x with each rep

11

EXcitation CHANnel codes:

0x Excite all reps with channel x
1x Increment chan x with each rep
2x Excite all reps with channel x, 60 Hz rej
3x Excite all reps with channel x, 50 Hz rej
4x Increment chan x with each rep, 60 Hz rej
5x Increment chan x with each rep, 50 Hz rej

13,14

CHANnel/LOCation:

If channel is indexed, parameter 3 becomes an input
location holding a voltage measurement.

13, 14

ThermoCouple TYPE codes:

x1 T (copper-constantan)
x2 E (chromel-constantan)
x3 K (chromel-alumel)
x4 J (iron-constantan)
x5 B (platinum-rhodium)
x6 R (platinum-rhodium)
x7 S (platinum-rhodium)
x8 N (nickel-chromium)

x = 0 Normal Measurement
x = 8 TC input from A5B40 isolation
x = 9 Output -99999 if out of common mode range

(Inst. 14 only)

15

Configuration codes:

ASCII

Hex Pair Binary

Logic level/Baud

00

10

20

TTL, 1200 baud

01

11

21

RS-232, 1200 baud

02

12

22

TTL, 300 baud

03

13

23

RS-232, 300 baud

18

OPTION codes:

0

seconds into minute (max 60)

1

minutes into day (max 1440)

2

hours into year (max 8784)

3

store year, day, hour, minute, second into 5 input
locations

20

8765, 4321 Each digit configures respective port

0

Set low

1

Set high

2

Toggle

3

1 ms Pulse

4

10 ms Pulse

5

100 ms Pulse

6

1 s Pulse

7

Configure as output

8

Configure as input

9

No change

22

EXcitation CHANnel/EXCITation mV:

If excitation channel is indexed, parameter 4 becomes
the input location from which to get the excitation voltage.

23

RANGE codes:

Fast (250 µs integration time)

Full scale range

13 ± 25 mV
14 ± 250 mV
15 ± 2500 mV

23

OPTION code, 4 digits:

ABCD
A

Trigger

0 Trigger on 1st analog channel

1 Digital trigger on C1
2 Same as 0, but sets C1 high during measurements

B

Trigger option

0 Trigger immediately
1 Trigger if above limit (high)
2 Trigger if below limit (low)
3 Trigger on rising edge
4 Trigger on falling edge

C

Destination

0 Input Storage
1 Serial port, 9600 baud
2 Serial port, 76800 baud
3 Serial port, 76800 baud to Storage Module

D Measurement

0 Differential measurement
1 Single-ended measurement

24

LOCation (start of 19 calibration values)

xxxx

Calibrate only when 24 is executed

xxxx--

(key in C before entering) store results of
automatic calibration

25

MASK:

Base 2 representation of ports 8-1; 1 means read,
0 means don’t read. Entered as base 10 (0-255).
Results are stored as base 2 converted to base 10.
1 indicates high, 0 indicates low or not read.

27

OPTION codes:

Code

Peak-to-Peak Volts

Max. Freq.

x1

2.0 mV

8 kHz

x2

3.0 mV

20 kHz

x3

12 mV

50 kHz

x4

2.0 V

200 kHz

x = 0

Output period in microseconds

x = 1

Output frequency in kHz

28

REPS: Hit C (--) to skip repeat of excit.

START Frequency of sweep (100s of Hz)
END Frequency of sweep (100s of Hz)

29

Enhanced Parameters

These parameters are listed on the manufacturer’s calibration
sheet, where:

CSI Par.

Enhanced Par.

04-23:

1-20

101

C:8765, C:4321 Each digit Configures respective channel

0

High level, rising edge

1

High level, falling edge

2

Low level ac, rising edge

3

Low level ac, falling edge

101

F:8765, F:4321 Each digit sets Function for respective channel

0

No value returned

1

Period, ms

2

Frequency, kHz

3

Time since previous channel, ms

4

Time since channel 1, ms

5

Counts on 2 since 1, interpolated

6

Low resolution frequency, kHz

7

Counts

8

Integral counts on 2 since 1

101

AVeraGing OPTion

0

Execution interval averaging

0--

Continuous averaging

xxxx

Specify average interval in ms

101

AVeraGing OPTion (continued)

xxxx--

Capture all events until xxxx edges of channel 1

9999--

Test Memory

102

FUNCTion

0

Channel state

1

Duty cycle

2

Counts

3

Memory test

105

SDI-12 CoMmanD codes:

Entry

Command

Description

0 M

Initiate

measurement

0--

C

Initiate concurrent measurement

1..9

M1..M9

Additional measurement commands

specified by the SDI-12 sensor

10

V

Initiate verify sequence

11

I

Send identification

20..29

R0..R9

Send command to sensor and retrieve data

106

TIME/VALues codes:

ttnn:

tt = time (seconds)
nn = No. values

107

OPTION codes:

0 Get data and measure

1..6,10,12,15,20,30,& 60 Execution Parameter

99 Get data after a group trigger

114

OPTION codes:

0 Set time with hr, min, sec values from 3 input locations
1 Set time with day, hr, min, sec values from 4 input

locations

2 Set time with yr, day, hr, min, sec from 5 input locations

119

MUltipleXer and PROBE selection:

ABCR
A

Level 1 multiplexer channel

B

Level 2 multiplexer channel

C

Level 3 multiplexer channel

R

Number of probes to be read, starting with the
channel specified by the ABC value

Enter 0 when level is not used.

119

OUTPUT options

0 Measure La/L
1 Collect waveform values
2 Collect waveform plus first derivative
3 Measure electrical conductivity

130

OPTION codes:

0 Watchdog errors
1 Table overruns
2 Low voltage counts
3 Lithium battery (volts)
4 Flash errors (CR10X-IM and CR10X-2M only)
10 Stores OS version, OS revision, and OS signature in three

consecutive locations

131

RANGE:

1 8 kHz @ 2 mV peak-to-peak
2 20 kHz @ 3 mV peak-to-peak
3 50 kHz @12 mV peak-to-peak
4 200 kHz @ 2 V peak-to-peak

138

PORT:

X

Specifies the first control port used. Subsequent repetitions
are enabled with the next higher control port.

1X All repetitions are enabled with the specified control port.

188

1

ST

PAR, 2

ND

PAR, 3

RD

PAR, 4

TH

PAR:

1ST PAR configures ports 16-13; 2ND PAR configures ports 12-9;
3RD PAR configures ports 8-5; 4TH PAR configures ports 4-1;
each digit configures respective port
0 Ouput logic low
1 Output logic high
2 Input digital, no debounce filter
3 Input switch closure, 3.17 ms debounce filter
4 Input digital interrupt enabled, no debounce filter
5 Input switch closure, interrupt enabled, 3.17 ms debounce filter
9 No change

INST.

01:

02:

03:

04:

05:

06:

07:

08:

09:

10:

11:

12:

49

SPA MAX

SWATH

1ST LOC

MAX LOC†

50

SPA MIN

SWATH

1ST LOC

MIN LOC†

51

SPA AVG

SWATH

1ST LOC

AVG LOC

52

RUNNING AVG

REPS

SOURCE

DEST

# IN AVG

53

A * X+B

START LOC

A1

B1

A2

B2

A3

B3

A4

B4

54

BLOCK MOVE

NO VALS

S LOC

S STEP

D LOC

D STEP

55

POLYNOMIAL

REPS

X

F(X)

C0

C1

C2

C3

C4

C5

56

SAT VP

TEMP

LOC

57

WB/DBT to VP

PRESSURE

DB TEMP

WB TEMP

LOC

58

LP FILTER

REPS

X

F(X)

WGHT F

59

RF (X/1-X)

REPS

X

MULT (RF)

60

FFT

LOG

2

(SMPL)

OPTION†

LOG

2

(AVG)

LOC

MULT

61

INDIR MOVE

SOURCE X

DEST Y

62

COV/CORR

VALUES

MEANS

VAR

S DEV

COV

CORRS

SAMPLES

S LOC

D LOC

63

EXT PARA 2-DIGIT †(8 parameters, depends on the inst. that 63 follows)

64

PAROSCIENTIFIC

VALUES LOC†

DEST LOC†

65

BULK LOAD

F

F

F

F

F

F

F

F

LOC

66

Z=ARCTAN(X/Y)

X

Y

Z

67

DYNAGAGE

B LOC

KSH

RESIST

AREA

CONDUCT

TC GAP

LF CUTOFF HF CUTOFF

OUTPUT†

D LOC MULT OFFSET

68

EXT PARA 4-DIGIT †(8 parameters, depends on the inst. that 68 follows)

INST.

01:

02:

03:

30

Z=F*10

EXP

F

EXP

Z

31

Z=X

X

Z

32

Z=Z+1

Z

33

Z=X+Y

X

Y

Z

34

Z=X+F

X

F

Z

35

Z=X-Y

X

Y

Z

36

Z=X * Y

X

Y

Z

37

Z=X * F

X

F

Z

38

Z=X/Y

X

Y

Z

39

Z=SQRT(X)

X

Z

40

Z=LN(X)

X

Z

41

Z=EXP(X)

X

Z

42

Z=1/X

X

Z

43

Z=ABS(X)

X

Z

44

Z=FRAC(X)

X

Z

45

Z=INT(X)

X

Z

46

Z=X MOD F

X

F

Z

47

Z=X

Y

X

Y

Z

48

Z=SIN(X)

X

Z

PROCESSING INSTRUCTIONS

(F is fixed value (constant); X, Y, & Z are input locations)

INST.

01:

02:

03:

04:

05:

06:

07:

08:

09:

10:

69

WIND VECTOR

REPS

SMPL/SUBINT†

SEN/OUT†

WS/E

WD/N

70

SAMPLE

REPS

LOC

71

AVERAGE

REPS

LOC

72

TOTALIZE

REPS

LOC

73

MAXIMUM

REPS

TIME†

LOC

74

MINIMUM

REPS

TIME†

LOC

75

HISTOGRAM

REPS

BINS

FORM†

B SEL LOC

WV LOC†

LOW LIM

HIGH LIM

77

REAL TIME

OPTION†

78

RESOLUTION

OPTION†

79

SMPL ON MAX/MIN

REPS

LOC

(must follow Inst. 73 or 74)

80

STORE AREA

AREA†

LOC/ID

81

RAIN HISTOGRAM

REPS

S LOC

SWATH

MEAN BINS

AMP BINS

LOW LIM

HIGH LIM

MIN AMP

OPTION†

D LOC†

82

STD DEV

REPS

LOC

69

SaMPLes/SUBINTerval (std dev):

0

No subinterval

xxxx

Number of scans per subinterval

SENsor type/OUTput codes:

x0

Avg WS,

Θ1, σ(Θ1)

x1

Avg WS,

Θ1

x2

Avg WS, resultant U,

Θu; σ(Θu)

x = 0 (anemometers & vanes)
x = 1 (north- & east-facing propellers)

Where:

Θ1 = Avg unit vector dir

σ(Θ1) = Std dev dir (Yamartino)

Θu = Avg resultant vector dir

σ(Θu) = Std dev dir (CSI)

73,74

TIME of max or min:

00 Max/min value only
01 With seconds
10 With Hour-Minute
11 With Hour-Minute, Second

75

FORM codes:

0

Open form (data beyond limits are
included)

1

Closed form (data beyond limits are
excluded)

WV LOCation:

0

Frequency Distribution

xxxx

Weighted Value Loc

77

OPTION codes:

xxx1

Seconds

xx1x

Hour-Minute

xx2x

Hour-Minute, 2400 at midnight

x1xx

Day

x2xx

Day, Previous day at midnight

1xxx

Year

(0 - no output, e.g., 110 = Day, Hr-Min)

78

OPTION codes:

0

Low resolution

1

High resolution

80

AREA codes:

1

Final Storage 1

2

Final Storage 2

3

Input Storage

81

OPTION:

00 Closed form/Fraction output
01 Closed form/Counts output
10 Open form/Fraction output
11 Open form/Counts output

D LOC

0

Send directly to Final Storage

xxxx First input location to store histogram

† Option Codes

Note: A Program Control instruction that sets the output flag high is
required to obtain output data from these instructions.

† Option Codes

49, 50

MAX/MIN:
0xxx

Store spatial max or min at loc xxx

1xxx

Store max or min at loc xxx & loc of max or min at xxx+1

60

OPTION codes:

0x

Power spectra

1x

Real and imaginary

2x

Magnitude and phase
x = 0 No taper
x = 1 Taper

63, 68

PARAMETERS 1-8:
Following Inst. 97 RF IDs & Phone No.: 1 digit at a time

32 Between RF IDs (e.g., repeater & site)
32 & 84 Between RF & Phone Modem No.
70 After last RF
13 To end

Following Inst. 98 (256 character limit) Base 10 value of
ASCII Character (1-99) 00 To end

64

VALUES LOC:

Start Loc: U(t), Tau, U0..T5

64

DESTination LOCation:

Start Loc: Temp (°C), pressure (psi), Signature

67

OUTPUT codes:

0

Short (sap flow, Kshapp)

1

Long (sap flow, Kshapp, dT, W, Qv, Qr, Qf)

OUTPUT PROCESSING INSTRUCTIONS

† Option Codes

INPUT/OUTPUT INSTRUCTIONS

CR10X INSTRUCTIONS AND PARAMETERS

}

Sets duration for subsequent
Pulse Port Command.

Advertising