CS125 Present Weather Sensor

16

Internal switch functions
Switch
number


Function

4

Reserved for future use

3

When switched to the ON position this switch temporarily sets the
CS125 communications port to a default RS232 communication state
(38400 bps). This is useful during field tests or maintenance when
the CS125 has been remotely configured for RS485 mode or a baud
rate your PC does not support. This change is temporary and will not
be stored to flash.
Once this switch is returned to its OFF position and the CS125 is
power cycled the CS125 will return to its previous communications
settings.

2

Reserved for future use, set to OFF.

1

When switched to the ON position this switch will reset the CS125 to
its factory default values. This reset will affect all communication
setting and will replace the user calibration settings with the factory
defaults. This will take immediate effect upon power up.

11. Message Formats: A breakdown of the different

default outputs of the CS125

– Basic/Partial/Full

The CS125 has three different standard message formats available to the user.
These three outputs are named Basic, Partial and Full. All parameters are space
delimited with a unique start and end character allowing easy storage into any
logger (see Section 15 on how to set default outputs). The SYNOP Full Format
message is the default message.

STX and ETX are hexadecimal command characters.