Hmp50 temperature and relative humidity probe, 1 temperature sensor, 2 relative humidity sensor – Campbell Scientific HMP50 Temperature and Relative Humidity Sensor User Manual

Page 6

Advertising
background image

HMP50 Temperature and Relative Humidity Probe

2.1 Temperature Sensor

Sensor: 1000

Ω PRT, DIN 43760B

Temperature Measurement Range: -40

°C to +60°C

Temperature Output Signal range: 0 to 1.0 VDC

Temperature Accuracy:

0

0.4

0.8

1.2

1.6

-0.4

-0.8

-1.2

-1.6

-20

-40

0

Temperature ( C)

o

( C)

Error

o

20

40

60

2.2 Relative Humidity Sensor

Sensor: INTERCAP

®

Relative Humidity Measurement Range: 0 to 98% non-condensing

RH Output Signal Range: 0 to 1.0 VDC

Accuracy at 20

°C

±3% RH (0 to 90% Relative Humidity)
±5% RH (90 to 98% Relative Humidity)

Temperature Dependence of Relative Humidity Measurement:

0

0.5

1.0

1.5

-0.5
-1.0
-1.5

10 20 30 40 50 60 70 80 90 100

RH (%)

( %RH/ )

Temper

ature Dependence

60 C

o

-40 C

o

C

o

Typical Long Term Stability: Better than 1% RH per year

Response Time (at 20

°C, 90% response to a steep change in humidity):

15 seconds with membrane filter

2

Advertising