NL120 Ethernet Module

d. Press the Apply button to save the changes and then close the Device

Configuration Utility.

A temporary IP address may be obtained from a DHCP server.

For more information, see Section 6.8, DHCP.

The NL120 must be connected to the datalogger before

configuring the datalogger with the Device Configuration Utility.

If it is not connected, the TCP/IP settings will not be displayed.

4.2.2 Step 2 – LoggerNet Setup

The next step is to run LoggerNet and configure it to connect to the datalogger

via the Ethernet port.

a. In LoggerNet’s Setup Screen, press Add Root and choose IPPort. Input

the datalogger’s IP address and port number. The IP address and port

number are input on the same line and separated by a colon. (The

datalogger’s default port number is 6785. It can be changed using Device

Configuration Utility or by modifying its value in the Status Table.)

b. Add a PakBus port and set the desired baud rate.

c. Add the datalogger (CR1000 or CR3000). Input the PakBus address of

the datalogger.

NOTE

NOTE

3