C.5 smcread error messages – Campbell Scientific PC208 Datalogger Support Software User Manual

Page 118

Advertising
background image

APPENDIX C. PC208 ERROR MESSAGES

C-4

Datalogger date xxx needs fixed!
The datalogger day is off from the computers
date. Check that the computer day is proper, if
it is then you must reset the date in the
datalogger using GraphTerm.

Datalogger clock xx:xx was fixed!
TELCOM reset the time in the datalogger to
match the time in the computer. Check the
.ERR file for information on what the time was
before it was fixed.

Communication error while fixing clock!
TELCOM was trying to reset the datalogger clock
when communication was interrupted. Check the
datalogger to see that the time is proper.

Communication or security error while fixing
clock!
TELCOM was trying to reset the datalogger
clock when communication was interrupted or
security was set in the datalogger. If security is
set then make sure that the .STN file has the
proper security number.

Datalogger clock xx:xx need fixed!
TELCOM found that the datalogger clock was
off. TELCOM did not reset the time, but only
reported it in the .ERR file. If you want it to
reset time automatically then you must select
the proper option in the .STN file.

PC201 battery is low!
Put a new battery in the PC201 card.

Could not open xxxxxx.dat file.
TELCOM could not open the .DAT file. Is the
disk full that TELCOM is trying to write too?

Warning: xx retries were logged.
TELCOM had to re-request data blocks xx
number of times. The data should be okay, but
you should check your data to make sure.

Maximum allowable time exceeded!
TELCOM stopped collecting data because the
maximum allowable time limit was exceeded.
Have you allowed enough time to collect the
data specified at the baud rate selected?

xxx.stn did not exist when logger called.
A datalogger called into the computer but the
xxx.STN file specified did not exist. You must
create a .STN file with the 3 digit ID that the
datalogger sends when it calls. Refer to the
TELCOM manual for further instructions.

C.5 SMCREAD ERROR MESSAGES

Error: No card found in slot number #
The PC cannot find the card in the slot
specified.

Error writing data to filename, check disk
space and try again.
A file system error has occurred when writing a
program file to disk. Check for available disk
space or disk corruption.

Program nn not found.
There is no program nn in the card.

Error - no room on card.
Shown when loading a .DLD program into a
memory card when there is not enough space
left.

Directory does not exist
When requesting the program to display a list of
files in a specific directory you have entered an
invalid directory name.

No matching files found
When requesting the program to display a list of
files using a wildcard character, no files of that
type could be found.

Inadequate disk space available!
When collecting data the program has found
there is not enough space to write the next data
block to disk.

Filename: xxxxxxx is too long - maximum 6
characters.
The file name you have specified is too long.
There must be space for the 2-digit index that
SMCRead appends to the end of the prefix of
the name.

Error opening xxxxxxx check if the file
exists, or is empty.
SMCRead was unable to open a specified file.

Error creating xxxxxxx check filename.
When creating a new file a disk error has
occurred. This may be because you have
specified an invalid file name.

Error writing data to disk, collection aborted.
An unforeseen error has occurred when writing
data to disk.

No data stored in the card!
The newest file does not contain any data!