Quick start, 1. the ps150 connected to a cr1000 and ac power – Campbell Scientific PS150/CH150 12 V Charging Regulators User Manual

Page 11

Advertising
background image

PS150/CH150 12 V Charging Regulators

100% to 50% approximately doubles the number of useful cycles available

from the battery

1

.

Leaving a lead-acid battery in a discharged state for

prolonged periods of time results in the undesirable growth

of large sulfate crystals (sulfation) that are detrimental to

battery performance.

VRLA batteries self-discharge at approximately 3% of rated capacity per

month at room temperature

1

. A 3% of rated capacity per month self-discharge

results in 100% discharge in approximately 33 months (≈ 3 years) for a battery

stored at room temperature. Self-discharge increasing with increasing storage

temperature.

Periodic recharging of stored batteries every few months is

recommended to prevent irreversible sulfation due to prolonged

time in a discharged state.

3. Quick Start

The PS150/CH150 modules are designed to handle extreme conditions. The

modules have been designed with mounting holes on one inch centers for

mounting to a standard Campbell Scientific enclosure back plate — see the

enclosure manual for mounting suggestions. See FIGURE 3-1 through

FIGURE 3-3 for typical enclosure installations using a PS150/CH150.

FIGURE 3-1. The PS150 connected to a CR1000 and AC power

CAUTION

NOTE

3

Advertising