Campbell Scientific SDM-CAN Datalogger to CANbus Interface User Manual

Page 56

Advertising
background image

Appendix B. A Summary of Data Types

B-2

Data
Type


Description

29

Read SDM-CAN status

Status Description

0000

The SDM-CAN has bus activities; error counters < 96.

0001

The SDM-CAN has bus activities; at least one error
counter is >= 96.

0002

The SDM-CAN is not involved in bus activities; error
counters < 96.

0003

The SDM-CAN is not involved in bus activities; at
least one error counter >=96.

30

Read SDM-CAN operating system and version number

31

Send Remote Frame Request.

32

Set SDM-CAN's internal switches

Switch Code Description

A

0

Not

used

B

0

returns the last value captured (default)

1

returns –99999 if value already read by

datalogger

C

0

Disable interrupts (default)

1

Enable pulse interrupts

2

Enable fast interrupts

3-7

Not

defined

8

Place the SDM-CAN into low power

stand-by

mode.

9

Leave switch setting unchanged.

D

0

Listen only (error passive) mode.

1

Transmit once.

2

Self-reception.

3

Normal

retransmission

4

Transmit

once

5

Self-reception; self -test.

6

Normal; self-test.

7

Active

at

power-up.

8

Not

defined.

9

Leave switch setting unchanged.

33

Read SDM-CAN's internal switches (see above)

Advertising