2 vdiv2.1, Wiring – Campbell Scientific VDIV10.1 and VDIV2:1 Voltage Dividers User Manual

Page 6

Advertising
background image

VDIV10.1, VDIV2.1 Voltage Divider Terminal Input Modules

H

L

or G

H

L

G

90 k

10 k

90 k

10 k

FIGURE 2-1. Voltage Divider Module Schematic

2.2 VDIV2.1

2:1 Resistive Divider
Resistors

10 k

Ω/10 kΩ

Ratio Tolerance @ 25

°C

±0.02%

Ratio

Temperature

coefficient

2 ppm/

°C

Power rating

0.25 W

Maximum Input Voltage

10 volts

3. Wiring

Each voltage divider module may be used to measure one differential voltage
(Figure 3-1) or two single-ended voltages (Figure 3-2).

Datalogger

H

L

AG or

G or

Shield

SENSOR
H Output

L Output

H

L

G

FIGURE 3-1. Wiring for Differential Voltage Measurement

2