Troubleshooting – Wesley Pack Mule User Manual

Page 24

Advertising
background image

24

EUV Owner’s Manual 2 May 22, 2009

Troubleshooting

Introduction

Be sure to follow all safety precautions when checking or repairing any part of the vehicle. Electrical
adjustments control system adjustments should only be made by qualifi ed personnel due to the use of
special equipment and instruments. If you have questions about the sensitivity or diffi culty of an adjust-
ment, call Wesley International at 800-241-2869.

Troubleshooting Tips

Problem

Possible Causes

What to Do

Vehicle does not run

Motor

Send the motor to an authorized motor
service center or replace the motor.

Small 10 amp fuse blown

Trace the wires from the fuse and check
for a short (any bare wire that touches
the chassis or common ground wire).

Faulty control circuit:

Solenoid
Battery
Key Switch
Fuse




Replace the faulty component.

Check all connections to ensure that all
are clean and tight.

Faulty batteries

Check electrolyte levels with a hydrom-
eter, and replace batteries if necessary.

Malfunction of motor controller

Check controller faults.

Consult the manufacturer and replace if
necessary.

Motor runs in the
wrong direction

Reversed toggle switch wires

Check the forward and reverse toggle
switch for proper connections.

Vehicle loses speed

Malfunction of solid state DC motor
controller or accelerator

Consult the manufacturer and replace if
necessary.

Advertising
This manual is related to the following products: