Maximum Criterion User Manual

Criterion, Installation

Advertising
background image

INSTALLATION

PROPER INSTALLATION IS IMPORTANT. IF YOU NEED ASSISTANCE, CONSULT A CONTRACTOR, ELECTRICIAN

OR TELEVISION ANTENNA INSTALLER (CHECK WITH YOUR LOCAL BUILDING SUPPLY, OR HARDWARE STORE

FOR REFERRALS). TO PROMOTE CONFIDENCE, PERFORM A TRIAL WIRING BEFORE INSTALLATION.

Form a drip loop with the wire at least eight inches
below the exit from the sensor and at least eight inches
below the point of entry into the building. Anchor any
exposed wire with insulated cable clips. Run the wire
through the building to the location where the indicator
will be located. Caulk any holes when done.

Feed the AC adaptor's cord and the sensor wire to the indicator.
Connect the the two wires of the AC adaptor cord to the back of the
indicator with the supplied brass nuts. The polarity does not matter.
Connect the two wires from the temperature sensor to #1 and #2
screw terminals (reading #1 through #5, left to rignt). The polarity
does not matter. Do not plug the AC adapter in until all of the
connections have been made and checked.

Mount the temperature sensor assembly with the two
large wood screws. Select a location that is protected
from direct sunlight and sheltered. (A north exposure, six
feet above the ground will give the best results.)

1

2

3

4

DRIP

LOOP

WOOD

SCREWS

CAULK

CABLE

CLIP

8"

MIN

TO

TEMPERATURE

SENSOR

AC

ADAPTOR

Mount the brass read-out directly over the cable
feed-thru-hole to avoid crimping the wire under the lip.
We recommend mounting the read-out on one of our
pre-drilled and centered panels. Plug the power supply
into a 110 VAC power outlet.

CABLE-HOLE

WA

LL

SCREW

SCREW

PANEL

Page 1

30 Barnet Boulevard

New Bedford, MA 02745

(508) 995-2200

CRITERION