Architect’s Specifications

Warranty

10-year limited warranty includes same day factory repair

or part replacement. Sensor 3 years. See owner’s manual

for details.

The dryer shall be manufactured by American Dryer to

include a 16 gauge reinforced steel cover with a white

enamel finish or 18 gage reinforced stainless steel cover

with satin finish. Recessed units will include a 16 gauge

steel wall mounting box. Motor shall be a shaded pole,

maintenance-free, brushless type. Motor requires no

brushes, oiling or fuses. This motor shall be thermally over-

load protected, 1/10 HP, 3200 RPM. Dryer shall deliver 160

CFM at 5500 LFM. Push button dryers shall be activated

by a cam-operated mechanical timer.

Cover shall be attached with one tamper-resistant bolt and

a 3” steel latch which locks it securely to base. Tamper-

resistant air intake vents, internal shield and side mounted

heating element are for additional safety. Heating ele-

ment is protected by an automatic resetting circuit breaker.

Nozzle and push button shall be zinc die castings with a

chrome plated finish. Nozzle shall revolve 360˚ unless

specified as fixed position. UL and C-UL listed. Made in the

U.S.A.

Operating Costs

The only operating cost for the DR series hand dryer is

electricity. Based on a cost of $0.10 per KWH:

Cost per 1,000 hand dryings

DR series = $1.92

Paper Towels = $20.56

(Refer to recessed instructions for recessed mounting)

WARNING: DISCONNECT POWER BEFORE INSTALLING

1. To remove cover, remove special Allen screw using wrench

supplied. Place a hand on each side of cover and pull bottom

toward you about 1/4 inch, then push cover up toward top of

dryer, releasing cover from mounting plate latch. Lift cover off

mounting plate by pulling forward at the bottom and upward at

the same time. DO NOT FORCE COVER OFF.

2. Dryers should be placed at least 2 feet (61cm) apart and at

least 12” (30cm) from washbasin. Do not install dryers over

washbasin. Hold the backplate to the wall at the suggested

mounting height. Measure from bottom edge of backplate to the

floor.

3. Mark the locations of the four mounting holes and the con-

duit entrance location on the wall. (The conduit entrance is the

proper hole diameter for 1/2 inch (13mm) conduit.)

4. Fasten the backplate to the wall where previously marked.

RECOMMENDATION:

Wood wall - No. 16 (M8) wood screws, 2 3/4”(70mm) long

Cement or brick - 1/4” (M6) stud expansion bolts, 3” (76mm)

long

Hollow wall - 1/4” (M6) toggle bolts, length depends on wall

thickness

5. Run service wire to dryer location and connect to terminal

block. IMPORTANT: All units must be supplied with a 3 wire

service. Use No. 12 wire or larger as required by local electrical

code. The ground wire must be connected to the dryer back-

plate. Unit must be installed by a qualified licensed electrician.

Do not connect any unit to a branch circuit over 20 amps.

Dryers located in shower rooms or other wet locations should be

equipped with ground fault interrupter(s).

6. Carefully replace the cover using tamper-proof bolts sup-

plied.

Installation (Surface Mount)

Mounting Heights:

Suggested mounting heights from floor to bottom of dryer:

MEN

WOMEN

CHILDREN

HANDICAPPED

“DR-N” Hand Dryer...

42” (107cm) 40” (102cm) 30-40” (76-102cm) 34” (86cm)

“DR-NH” Hair Dryer...

72” (183cm) 68” (173cm) 46-68” (117-173cm) 52” (132cm)

Dimensions:

WIDTH

HEIGHT

DEPTH

NET WEIGHT

Surface Mounted

11”

9-1/4”

6-5/8”

16 lbs. (7kg)

Recessed Mounted

14-1/8”

14-1/8”

3-3/8”

23 lbs. (10kg)

DR Series Surface Mounted

9 1/16

(230 mm)

9 1/2

(241 mm)

5/8

(17 mm)

10 13/16

(274 mm)

7 7/16

(189 mm)

1 5/16 (33 mm)

5/8 (17 mm)

7/8 (22mm) DIA. IN-WALL

CONDUIT ENTRANCE

1 (25 mm)

(4) MTG HOLES

5/16 DIA. (8 mm)

2 3/4

(70 mm)

1 1/4

(32 mm)

5/8

7/8 (22mm) DIA. SURFACE

CONDUIT ENTRANCE

DR Series Recess Mounted

ROUGH

OPENING

11 3/4” W (30cm)

X

12 3/4” H 932cm)

US