Maximum Stratus User Manual

Stratus, Installation

Advertising
background image

STRATUS

INSTALLATION

30 Barnet Boulevard

New Bedford, MA 02745

(508) 995-2200

PROPER INSTALLATION IS IMPORTANT. IF YOU NEED ASSISTANCE, CONSULT A CONTRACTOR, ELECTRICIAN

OR TELEVISION ANTENNA INSTALLER (CHECK WITH YOUR LOCAL BUILDING SUPPLY, OR HARDWARE STORE

FOR REFERRALS). TO PROMOTE CONFIDENCE, PERFORM A TRIAL WIRING BEFORE INST

TION.

ALLA

1

Remove the cover of the Humidity sensor to gain
access to the holes on the upper left and lower
right side of the sensor. Mount the sensor to the
wall with two wood screws. The sintered bronze
sensor house should face toward the ground.
Select a location that is protected from direct
sunlight. (A northern exposure about six feet
off the ground with good air flow will give the
best results.)

CAULK

8"

MIN

COVER

WOOD SCREWS

2

Form a drip loop with the wire that
is at least eight inches below the
exit point of entry. Anchor any
exposed wire with insulated cable
clips. Run the wire through the
building to the location where the
indicator will be located. Caulk any
holes when done

DRIP

LOOP

SENSOR

BRONZE

SENSOR

HOUSE

CABLE

CLIP

Feed the AC adaptor’s cord to the rear of the indicator.
Connect the two wires of the AC adapter cord to the
indicator using the brass nuts supplied in the hardware
pack. The polarity does not matter.

3

1

2

3

TEST POINT 1

Test

Point:

INDICATOR

AC

ADAPTER

NUTS

BRASS