Programming

7

AXB-VOL3 Three-Channel Volume Control

AXB-VOL3 Send_Commands (Cont.)

PP

Syntax:

SEND_COMMAND VOL, ’P<Channel> = P<Channel>’

Variable:

Channel = Enter channel number.

Examples:

SEND_COMMAND VOL, ’P1 = P2’

Sets channel 1 level to the same as channel 2.

SEND_COMMAND VOL, ’P1 = P3’

Sets channel 1 level to the same as channel 3.

SEND_COMMAND VOL, ’P2 = P1’

Sets channel 2 level to the same as channel 1.

SEND_COMMAND VOL, ’P2 = P3’

Sets channel 2 level to the same as channel 3.

SEND_COMMAND VOL, ’P3 = P1’

Sets channel 3 level to the same as channel 1.

SEND_COMMAND VOL, ’P3 = P2’

Sets channel 3 level to the same as channel 2.

Note: You cannot use 'P0' with these commands.