The ADC SignalOn

®

RF Switch Module (RFSM) is designed for use with the

SignalOn 8-position, or 20-position powered chassis. All RF connections to the
switch are made through standard 75 W BNC, or F connectors on the rear of the

module. All operating controls and indicators are located on the front panel with
configuration controls located on the rear of the module.

The primary function of the module is to monitor the RF signal gain of the operating
primary “A“ input, and switch to the backup “B“ input if the gain of the primary
path rises, or falls below the pre-set customer selected threshold. Should the “A“
input side go above, or fall below the threshold of the unit, the RFSM will rapidly
switch the input from the failed input to the secondary input. This switch usually
is less that 10 milliseconds. Switch status, failure LEDS, and RF level bar graphs are
mounted on the front panel of the switch module. Switching threshold: +/- 3 dB or
+/- 6 dB, and alarm contact closures are located on the rear of module.

Dual RF Switch

Module

Actives: RF Switch Modules

Features

Continuous monitoring of primary and secondary

Detects both high and low power failures

User-selectable switching threshold:

+/- 3 dB or +/- 6 dB

Fail-over switching time < 10 ms

Automatic switchback after "A" path is restored

Front-panel LED status and dual power

level displays

Alarm contact for remote failure monitoring

Available in BNC and F-connector configurations

Single or dual modules

Easily configured for redundancy or A-B

switch applications

Front panel bar graph display provides indication

of RF power and switching threshold

Indication of switch status provided by front

panel LED and rear terminal block contacts

Easily configured switching threshold levels via

rear DIP switch

One-step calibration

Auto switch-back feature to primary input

Built-in delay to prevent from false switching

Automatic or manual modes of operation

NEBS Level 3 compliant

O r d e r i n g I n f o r m a t i o n

Description

Catalog Number

Redundant RF Switch Modules

BNC connector

Single circuit

N-MRFSM1-B

Dual circuit

N-MRFSM2-B

F connector

Single circuit

N-MRFSM1-F

Dual circuit

N-MRFSM2-F