Installation

19

510969

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Step 4: (Electric Dryer Only) Connect
Electrical Plug

For further assistance, refer to section on Electrical
Requirements
.

IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three conductor power supply
cord kit rated 240 Volts (minimum) 30 Amperes
and labeled as suitable for use in a clothes dryer.

Figure 12

NOTE: For more detailed information on
connecting three-wire or four-wire plugs, refer to
section on Electrical Connection
.

NOTE: Four-wire cord is required for mobile
homes or where codes do not permit grounding
through neutral.

Figure 13

D275I

D006I

1

Typical Receptacle

2

Power Cord

3

Strain Relief Nut

4

Strain Relief

1

2

3

4

THREE-WIRE

1

2

3

4

FOUR-WIRE

D679I

D680I

NOTE: Dryer is shown with access cover removed for
illustration purposes only. NEVER operate the dryer
with access cover removed.

1

Ground Wire

2

Ground to Neutral Wire

3

Neutral Terminal

4

“L2” Terminal

5

Center Wire (Neutral)

6

Strain Relief (Not supplied with dryer)

7

Ground Screw

8

“L1” Terminal

9

Black Wire

10

White Wire (Neutral)

11

Red Wire

D679I

1

8

7

6

5

4

3

2

THREE-WIRE CONNECTION

D680I

1

8

7

6

10

4

3

1

11

9

FOUR-WIRE CONNECTION