4

598-1094-04

70 ft.

(21 m)

8 ft.

(2.4 m)

240°

Maximum Range

Maximum

Coverage Angle

100 ft.

(30.5 m)
Boosted

Motion

Motion

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

Walk through the coverage

area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area.

Keep the sensor at

least 1" (25 mm) away from
the bulbs.

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

Secure the sensor head by
tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 20 minutes).

Set the Dual Light Level switch to the amount of

time after dusk you want the lights on at low level
(Off, 3, 6 Hrs., Dusk-to-Dawn).

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Least Sensitive

Most Sensitive

Sensor

WARNING: Risk of fire. Do not aim the bulbs

at a combustible surface within 3 ft. (1 m).

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Turn the RANGE control to the medium position

(halfway between MIN and MAX), Dual Light Level
to OFF, and the ON-TIME control to the TEST
position.

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME DUAL BRITE

TEST 1 5 2 0

MINUTES

OFF 3 6 DUSK TO

HOUR DAWN

DUAL LIGHT LEVEL