7

TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.

COMPONENT TESTING PROCEDURES

Component Electrical Testing (with ohmmeter)

Thermistor resistance 10K Ω @ 25°C 77°F

Thermostat 1 resistance < 1Ω

Thermostat 3 resistance < 1Ω

- If resistance is infinity, replace thermostat 3.

Thermostat 2 resistance < 1Ω

- If resistance is infinity, replace thermostat 2.

[

DUAL

] Heater resistance 13 Ω (PIN 2-3) Heater

resistance 34 Ω (PIN 1-2)

- If resistance is infinity, replace Heater.

[

SINGLE

] Heater resistance 10 Ω (PIN 1-3)

- If resistance is infinity, replace Heater.

1

2
3

Measure resistance of the following terminal

1) Door switch : off

Terminal : “COM” - “NC” (1-3) < 1Ω
Terminal : “COM” - “NO” (1-2) : ∞ Ω

2) Door switch : On

Terminal : “COM” - “NC” (1-3) : ∞ Ω
Terminal : “COM” - “NO” (1-2) < 1Ω

Belt Cut-off S/W

- Lever open: Resistance value < 1Ω

- Lever push: Resistance value : ∞ Ω

Lamp resistance : ∞ Ω, (-) : BLU, (+) : WHT

Motor (Electronic & GAS)

Contacts

Function

1M

2M

3M

5M

6M

Start

Run

= Contact closed

Centrifugal Switch (Motor)

2.88Ω between
Pin# 3 and 4

3.5Ω between
Pin# 4 and 5