Level

Message

Status

Solution

0

The “Vent Sensor

lamp is turned off.

The ductwork is free from

blockages.

-

1

The “Vent Sensor ”

lamp illuminates.

When a part of the duct or

the lint filter is blocked by lint

or a foreign object.
When the resistance is high

because the duct is too long

or bent.

Check the duct

connection and shorten

the duct and straighten it

if necessary.
Check the lint filter or

the duct and clean it if

necessary.

2

The “Vent Sensor ”

lamp blinks.

When the duct is blocked by

lint or a foreign object.
When the resistance is very

high because the duct is too

long or bent excessively.

Check the duct

connection and shorten

the duct and straighten it

if necessary.
Check the lint filter or the

duct and clean it as soon

as possible.

In the LEVEL 2 state, this lamp blinks for 3 hours after the completion of the cycle. (If the wrinkle

prevention function is activated, this message is displayed for up to 3 hours.)
If the power button is pressed or the door is opened, the power is immediately turned off.

For more information about the duct installation, please refer to the “Ducting requirements”
section on page 8.

• Although the dryer is available even if the blockage message is displayed, the drying time
may be extended.
• If the LEVEL 1 message is displayed the first time the dryer is run after the installation,

check the connection and clean the duct. If the LEVEL 1 message appears even
after you have checked and cleaned the ducts, this may indicate that there are some
restrictions of the duct due to the length, condition, etc.
If this occurs, you can use the dryer normally and no countermeasures need to be taken.
However, the drying time may be extended or the drying performance may be degraded.