Alignment and adjustments, Continuous run mode, Data display mode – Samsung DV433ETGJWR-A1 User Manual

Page 4: Warning

Advertising
background image

4

Continuous Run Mode

How to enter:
-

Press Mixed Load Bell+ Dry Level for 7 sec during Power On State (normal user mode).

-

Once in Continuous Run Mode, display “CC” for 1 sec and the remaining time for 2 sec in

turns.

-

The previous cycle will restart during Continuous Run Mode until the mode is deactivated.

-

During Continuous Run Mode, press Mixed Load Bell+ Dry Level for 7 seconds to go back to

normal user mode.

Data Display Mode

How to Enter:
-

With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a

beeping sound .

-

If not pressed any keys for 5 minutes, it will be set back from Data Display Mode

-

If pressing AdjustUp Key in this mode ,Display Mode will be incresed.

-

If pressing AdjustDown Key in this mode ,Display Mode will be decresed.

Definition of Data Display Mode:
-

Display Mode 1 : Temperature data

-

Display Mode 2 : Average Touch Sensor data for 1 minute

-

Display Mode 3 : Average Temperature data for 1 minute

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.

Power On state

(Normal user mode)

Mixed Load Bell+ Dry Level

7 SEC

Continuous Run Mode

Technical_information-02835F_EN.indd 4

2012-05-18 �� 4:34:40

Advertising
This manual is related to the following products: