10_ Connecting the power

Installing a 4-wire conduit

• Aluminum building wire may be used but it must be rated for the correct amperage and voltage to

make the connection. Connect wires according to this Step 4 depending on the number of wires.

• Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local

codes.

1. Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and

ground plate and retain them.

2. Cut and discard the ground strap. Do not discard any screws.
3.
Insert the ground bare wire tip between the range frame and the ground plate (removed earlier)

and secure it in place with the ground screw (removed earlier).

4. Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening.
5. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.
6. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the

screws since it could damage the wires.

7. Go to step 5 and proceed with the installation.

Ground strap

Ground plate

White

Black

Red

Neutral
terminal

Ground
wire

(Green)

Wire tips

White

Black

Red

stEP 5. REPlACinG thE ACCEss CoVER

Replace the access cover on the range back. To replace the wire cover, insert double projections in the
pockets located below the opening and tighten the screw.

Installation-USA DG68-00108E-01_EN.indd 10

2011-03-18 �� 4:06:29