Alignment and adjustments, Warning – Samsung WA456DRHDWR-AA User Manual

Page 3

Advertising
background image

ALIGNMENT AND ADJUSTMENTS

3

NO

Error Code

(Diagnostic Code

Error Image)

Description

Corrective Action

11

MICOM is attempting to drive the motor

but is not getting any response signals

from the hall sensor. Visual check shows

motor is not running. (Locked, Defective

Hall Sensor or Overload)

Evaluate wire harness for loose or

unhooked connections. Go to “

Quick Test Mode” and test Motor.

12

(WA422*/WA400*)

The hot/cold water hose connection

is not correct.

Please connect the hot/cold water

hose connection correctly.

(WA456*)

13

Suds is detected during the washing

session. (“SUd” or “Sd” is not an error.

When it finishes washing, End and

the “SUd” or “Sd” code will blink in

turn.)

Guide a user to reduce amount of

detergent usage.

14

Communication error between SUB

PBA and MAIN PBA

Check Main PBA, SUB PBA & Wire-

harness. Replace PCB

15

If the MEMS communication error or

MEMS trouble diagnosis error occur,

this message will be displayed.

1. Check the MEMS sensor and PBA.

2. Check the wire connector

terminals

16

A button except the Power button is

continually pressed.

Check whether either the Power

switch or a tact switch is continually

pressed

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.