Installing your dryer, Ducting requirements – Samsung DV457E1GSGR-A1 User Manual

Page 12

Advertising
background image

English - 12

Installing your dryer

DUCTING REQUIREMENTS

• Use a 4-inch (10.2 cm) diameter rigid aluminum or rigid galvanized steel duct.
• Do not use a smaller duct.
• Ducts larger than 4 inches (10.2 cm) in diameter can result in increased accumulation of lint.
• Lint should be removed regularly.
• If a fl exible metal duct must be used, use the type with a stiff sheet metal wall. Do not use a fl exible duct

with a thin foil wall. A serious blockage can result if the fl exible metal duct is bent too sharply.

• Never install any type of fl exible duct in walls, ceilings, or other concealed spaces.
• Keep the exhaust duct as straight and short as possible.
• Secure joints with duct tape. Do not use screws.
• Do not use plastic fl exible duct. Plastic fl exible duct can kink, sag, be punctured, reduce airfl ow, extend

drying times, and aff ect dryer operation.

• Exhaust systems longer than recommended can extend drying times, aff ect machine operations, and

collect lint.

• The exhaust duct should end with an exhaust hood with a swing-out damper to prevent back drafts and

entry of wildlife. Never use an exhaust hood with a magnetic damper.

• The hood should have at least 12 inches (30.5 cm) of clearance between the bottom of the hood and

the ground or other obstruction. The hood opening should point down.

• Never install a screen over the exhaust outlet.
• To avoid lint buildup, do not exhaust the dryer directly into a window well. Do not exhaust under a house

or porch.

• If the exhaust duct must run through an unheated area, the duct should be insulated and slope slightly

down towards the exhaust hood to reduce condensation and lint buildup.

• Inspect and clean the interior of the exhaust system at least once a year. Unplug the power cord before

cleaning.

• Check frequently to make sure the exhaust hood damper opens and closes freely.
• Check once per month, and clean at least once per year. Note: If your clothes are not getting dry, then

check the ducting for obstructions.

• Do not exhaust the dryer into a wall, ceiling, crawl space, or concealed space of a building, gas vent, or

any other common duct or chimney. This could create a fi re hazard from the lint expelled by the dryer.

ELECTRIC AND GAS DRYER

Weather Hood Type

Recommended

Use only for short-run installation

4” (10 .16 cm)

2.5” (6.35 cm)

No. of 90° elbows

Rigid

Metallic Flexible*

Rigid

Metallic Flexible*

0

24.4 m (80 ft.)

12.4 m (41 ft.)

22.6 m (74 ft.)

10.1 m (33 ft.)

1

20.7 m (68 ft.)

11.2 m (37 ft.)

18.9 m (62 ft.)

8.8 m (29 ft.)

2

17.4 m (57 ft.)

10.1 m (33 ft.)

15.5 m (51 ft.)

7.6 m (25 ft.)

3

14.3 m (47 ft.)

9.0 m (29 ft.)

12.5 m (41 ft.)

6.5 m (21 ft.)

* Do not use non-metallic fl exible ducts.

DV457E1_02836J-06_EN_140428.indd 12

DV457E1_02836J-06_EN_140428.indd 12

2014-04-28

5:30:04

2014-04-28

5:30:04