13

14

Analog
Adjunct

3.5 mm

Phono Plug

from

Recording

Device

10

!

WARNING:

Analog adjuncts and the recording device must be co-located with the 2420 Telephone and 20-type
stand.

The distance between the 200-type module and the analog adjunct should not exceed 3 meters in the
EU countries.

The distance between the 201-type module and the recording device should not exceed 200 feet/60.96
meters.

For the 201-type module, the record output impedance is approximately 600 Ohms, and the output
channel is isolated from the telephone via a voice transformer that meets the UL 60950 Dielectric
breakdown requirement of 1,000 VRMS for one minute.

Slot 2

--

200-Type

200-Type

200-Type

Slot 1

201-Type

200-Type

--

201-Type

Supported Module Combinations